BuildingGreen Report

Forum topic

Wondering if we can have a dialog on HVAC load calculation software... we are currently still using Trane Trace 700, but with the future migration to Trace 3D+ coming are looking into other options. Never used HAP but I haven't heard great things, and we dabbled in IES VE for a while, but went back to Trace since at that time there was no... Read more

Forum topic

Greetings friends.  Our leadership has decided to create a partner-position to my role but in the engineering group of our firm.  This person would be a key ally in my work improving the high performance and sustainability of our projects with a focus on high-performance mechanical systems, net-zero, electrification, etc...  If you are... Read more

Forum topic

Hi All -

I'm wondering if any of our SDL people have a project case study on designing for deconstruction that they'd like to present on? I know there are a lot of conversations that we should be designing for deconstruction but has anyone done a focused project?  Thank you for any input you might have.

Forum topic

Have you ever been accused of being "self-righteous," or "judgemental" in your role as and SDL? Anyone have tips and tricks to avoid this trap? 

Forum topic

Anyone using the USG EcoSmart drywall? I'm writing a short product review and am looking for some quick feedback. I'm particularly curious about reduced greenhouse gas emissions and overall cost. Thanks! Brent

Forum topic

Keith Hempel, Julie Hiromoto, and Billie Faircloth have been elevated to the AIA College of Fellows - I'm sure I'm missing others but congratulations! Can't wait to celebrate in person - I still rememer Lance Hosey in his tux and Beth Heider in a full ball gown at the AIA Fellows dinner in Chicago (the only one I ever attended. . .) 

Peer Network Event

Quiz

Welcome to the quiz portion of How to Spot Greenwash--A BuildingGreen Webinar.

Learning Objectives
Upon completing this course, participants will be able to:


 

1. Understand the characteristics of quality standards and certifications to help screen out greenwash.
2. Recognize strengths and weaknesses of... Read more

Team Group

Forum topic

Hi,

I imagine you've already considered this, but I wanted to mention it before you cross the point of no return...

The name "BIT Building" has the potential to be misunderstood out of context because it sounds like it has something to do with Bitcoin.  I don't think this is a huge problem, but you may want to evaluate the risk... Read more

Forum topic

Has anyone used Insight for Revit to document the LEED Daylight Credit If so, would you recommend it?

Thanks,

_Ilana

Forum topic

Hi, all.

Has anyone used Unicel's Timber Curtain Wall System? It uses engineered glulam wood mullions on the inside with aluminum mullion caps / butt joints. Has anyone gotten close to using it, but couldn't get it procured for a particular reason? They note up to 72% more energy efficienct than a conventional aluminum curtain wall and... Read more

Author

Emma's role at BuildingGreen includes coordinating social media activity, setting up and scheduling weekly emails, and completing various marketing projects. She is also responsible for ensuring that members receive continuing education credits.

... Read more

Product Guide

Indoor pollutants can cause health problems and disrupt HVAC system functioning.

BuildingGreen-Approved Filtration

BuildingGreen approves a variety of equipment, filters, and pre-filters that remove particulates and contaminants, minimize pressure drop, or reduce pollution from operations. Products include:

MERV 13 or higher... Read more

Forum topic

Hi All

I'm wondering if any of you know how to track the GWP for materials that do not have an EPD?  I'm trying to do a carbon comparison on batteries but neither one has an EPD that I can find.  Thanks for any guidance you may have. 

Forum topic

Our guys have started talking about how the built enviroment can address infection transmission in public spaces - places like lobbies and waiting rooms, particularly in applications where people queue - theaters, airport gates, amusment parks, etc.  In the specific case of Covid-19, we know the microbe can be transmitted three ways:  fomite (... Read more

Forum topic

Greetings, SDL network - We are attempting to resolve an issue with how data center projects calculate baseline EUIs for the AIA 2030 Commitment and could use some help from this network. With projects that comply with code prescriptively (i.e. not energy modeled), we have found the default baseline assumptions within the DDx platform are not... Read more

Forum topic

Curious what people's 'best' experiences or recommendations are for load calculations and energy modeling regarding electrochromic glazing... hoping I can lean on others as it's just now becoming more of a talking point in our market here in Omaha. 

Specific questions including whether load and energy modeling software are separate (... Read more