Forum topic

Hi, all. We missed you at the standing check in today. We have a couple of questions for the BG team:

1. What is the timing criteria you need for Best Practice content? We need to back into a deadline on submissions and believe your critical path timing will help define ours.

2. Can you elaborate on what LEED User/BG content may... Read more

Forum topic

Hey SDL,

I'm curious if anybody out there has developed specification language requiring a certain level of airtightness (as assessed via one or a series of blower door tests) for a commercial project when it is not going for a Passive House certification and a blower door test is not required by code--basically, something in the... Read more

Forum topic

We have an MEP engineer that is calculating peak loads at about 6 times passive house levels on a large commercial building that is at or near passive house levels of insulation and air infiltration. We suspect one reason is that he is figuring a 50% efficiency level for the ERV. We are showing him ERV systems with 80-90% efficiency, but they... Read more

Forum topic

Hi all,

We have a newly constructed, core/shell project having some hot water issues in the core restrooms.

There is a 0.35 Toto lav installed throughout. The hot water heaters are adjacent on each floor, located in the janitor closets. We did the math, and there could be a gallon of water standing and cooling in the pipe between... Read more

Forum topic

Hi All,

Has anyone dug into ASHRAE 2016 as part of the new v4.1 requirements or as codes start to adopt it? I recently presented on this and thought I should check my math to make sure I'm understanding and communicating this correctly.

My understanding is that there is a new reference baseline, that is essentially the ASHRAE 2004... Read more

Quiz

Welcome to the quiz portion of Resilient Design—Smarter Building for a Turbulent Future.

Learning Objectives
Upon completing this course, participants will be able to:


 

1. List three motivators for resilient design and at least three actions that address each motivator.
2. Explain why climate change isn't our... Read more

Forum topic

Hello - 

I am looking for the recording and the PDF/ slides that were shared 3/6 for the project process share-out/ 5 min presentations. It was super inspiring and I would like to refresh my memory of some of what was shared. Thank you!


Alison Nash 
AIA, LEED AP ID+C, CPHC, WELL AP
Associate | Sustainability... Read more

Forum topic

Hi SDLers! I hope early fall is finding you well.

There is a current opportunity to make a difference in the campaign to reduce use of toxic flame retardants.

Arlene Blum and the Green Science Policy Institute, whom many of you know, are currently organizing a campaign of support for the CA State Fire Marshal's proposal to allow... Read more

Forum topic

We are having trouble sourcing a LEED compliant wallcovering adhesive. We specified Roman Pro-880 which is low VOC but doesn't have sufficient back up for TVOCs. Have you had success with other products?

Forum topic

Dear SDL: Thanks to all who have already given their support to the AIA Resolution on Urgent and Sustained Climate Action. We're into the final push of getting out the vote to pass the resolution next Wednesday, June 5th afternoon in Las Vegas. This requires 2/3s of the voting delegates to pass. So we're asking anyone who 1) is attending as a... Read more

Forum topic

Hi Everyone, 

Has anyone had success in finding organizations or programs that will recycle the hard hats? We are looking into options for recycling our expired hard hats that can no longer be used. Ideally, we would want to use a company with facilities across the country but we are open to any suggestions or ideas you all may have.... Read more

Forum topic

Hello all,

This month's SCDL call was full of great discussion! We decided this month that we are feeling good about where we are for the Task Force Agreement on defining social sustainabiltiy in our work. The aim is to work with this agreement for a while and see if it holds up as a process framework. There was also interest to invite... Read more

Campus-wide Group

Forum topic

Hello,

We’re looking for Design Energy Code Equivalents for Chinese commercial energy codes. Do any of you have  any good sources? I’ve only found data comparing ASHRAE 90.1 2013 to the Chinese Code at that time. We understand the Chinese code require a 65-75% energy savings over the baseline but don’t have good information for defining... Read more

Quiz

Welcome to the quiz portion of Building Electrification: A Vital Solution to Climate Change.

Learning Objectives
Upon completing this course, participants will be able to:


1.  Understand the relationship between building electrification and decarbonization to improve the efficiency and sustainability of buildings.

2... Read more

Forum topic

It is with the greatest pleasure that I announce to this esteemed group the recognition of our very own and much-loved leader Nadav Malin as an Honorary AIA member. AIA COTE had the honor to serve as Nadav's sponsor and we are pleased and delighted with this outcome (but not surprised of course.) For the record, "The AIA recognizes the notable... Read more

Forum topic

On a large sports project, we worked with the structural engineer to spec low carbon / high SCM concrete mixes. Much of the floor area will be sealed and polished concrete, and a concrete sub is pushing back on the SCMs saying they should not be above 20% (with a preference for 0%) for the polish to finish properly, per the manufacturer. Anyone... Read more

Campus-wide Group