Forum topic
Hi GGs,
We are looking to do a renovation of a very leaky old office space, and we want to get a good snapshot of air quality and effective envelope R values both before and after.
Does anyone have experience with:
1. installing heat flux sensors on windows and walls
2. deploying IAQ measurement devices that can log... Read more
Forum topic
Embodied carbon in products and existing buildings. What does LCA tell us about renovation vs. new construction and material choices?
Guiding Questions:
What easy ways are there to communicate about embodied carbon? Are there easy ways to calculate it? What do I need to know about LCA? Are there any found patterns of when it... Read moreProduct Guide
Preservative treatments extend the service life of wood, but many such treatments are highly toxic, especially to aquatic life.
BuildingGreen-Approved Preserved Wood
Products approved by BuildingGreen use chemicals (commonly borates) that are relatively low in toxicity and have low VOC emissions.
Health and Environmental... Read more
Forum topic
Hi all,
Here's a good follow up to Maria's steel question on Monday. We have a Midwest project that unfortunately (from a carbon perspective) is required to use a traditional, thick precast facade. We’re working with the contractor and potential future (not yet bid out) fabricators to determine an appropriate % of pozzolanic material... Read more
Quiz
Welcome to the quiz portion of Measuring Energy Use in Buildings: Do Our Metrics Really Add Up?.
Learning Objectives
Upon completing this course, participants will be able to:
1. Explain the differences between site energy, source energy, and energy cost.
2. Summarize three ways in which source energy can... Read more
Forum topic
Has anyone here had success in comparing life cycle impacts for different window system options? We have been trying to compare different options but have only been able to source one expired EPD for an actual window (frame + glazing). Is the typical approach to separately compare glass and framing options? Are we missing something or is there... Read more
Forum topic
Seems to be a trend! We're looking to fill a Sustainability Specialist position at Perkins Eastman:
http://perkinseastman.hrmdirect.com/employment/job-opening.php?req=89745...
Please let me know if you have any potential candidates who might be a good fit!
Forum topic
is anyone aware of some guidance about citation protocols for when a person/team/org uses an AI tool to generate some base components for a report (which is then heavily edited by humans)?
I'm inclined to disclose in detail which tools were used and how ... but would love to know if there are some industry protocols shaping up about this... Read more
Forum topic
Hi there Hive Mind! Hope everyone's doing well and staying cool in the heatwave all over.
An engineer on one of my projects reached out about contact switches for operable windows that are empowered to shut down the associated FCU in dormitory bedrooms when the window is open. This functionality allows the FCU to run at something like... Read more
Forum topic
Apologies if some of you are seeing this for the second time - on behalf of Frances Yang, Mike Gryniuk and the Carbon Leadership Forum, consider signing on in support of the SE 2050 Challenge for structural engineers. (Yes, there is an option to sign on as a non-structural engineer, in support of the program.)
http://... Read more
Forum topic
Hi Leaders,
If your experience was anything like mine, it was a stressful night. I'm feeling a hunger for talking with smart, passionate people about what this all means.
I'm not interested in making this into a political forum--we can all get plenty of that elsewhere. But if you'd like to hang out and just process how you're... Read more
Forum topic
Hey all,
Question for those of you who do in-house daylight analysis about modeling translucent glazing.
We use ClimateStudio for our modeling. It has plenty of material options for clear glazing but nothing for translucent glazing, and we are trying to understand the impacts of a translucent interlayer at some skylights. We can... Read more
Peer Network Event
Spotlight Report
Remember 2013? LEED version 4 had just been released to the public. Hardly anyone was using it, though—not only because they didn’t have to, but also because there just wasn’t a pathway to achieve many of the new credits in the rating systems. Especially the product-related credits in the Materials & Resources category, along with the Low-... Read more
Forum topic
The AIA is NOT announcing the COTE Top Ten award winners this Wednesday. Both the firm and student juries were held last month and winners were chosen. But the AIA is focused on COVID-19 info only now, restricting other communications. That is why the COTE newsletter has disappeared from your mailboxes.
Maybe i am the only one who... Read more
Forum topic
I am working on a new community development in St. Paul that is striving to achieve net-zero energy. We are able to get there mathematically by using the extra generation on light industrial rooftops to offset medium-density housing energy use (all buildings are anticipated to have different, private owners). However, this puts us over... Read more
Product Guide
Plug loads—the energy consumed by plugged-in devices—can use a substantial amount of the total energy in both residential and commercial buildings.
BuildingGreen-Approved Controls
BuildingGreen approves products that monitor and reduce electricity use for plugged-in electrical devices.
Plug Loads and Energy Conservation... Read more