Forum topic
We have an MEP engineer that is calculating peak loads at about 6 times passive house levels on a large commercial building that is at or near passive house levels of insulation and air infiltration. We suspect one reason is that he is figuring a 50% efficiency level for the ERV. We are showing him ERV systems with 80-90% efficiency, but they... Read more
Forum topic
Hi All,
Jacob Knowles from BR+A reached out with a request and I’m passing it on to you all. Jacob’s contact info is at the bottom of this so you can respond to him directly or respond here and I’ll forward it on:
We are working on assembling examples of large wet lab buildings that employ strategies to greatly reduce fossil... Read more
Forum topic
Hi all, has anyone come across a comprehensive (and recent) study looking at how long buildings actually last (beyond Stewart Brand)? I know of plenty that look at the benefits of reuse, but none that look at existing building stock and how much has been reused vs. demolished.
As we start looking at embodied carbon metrics, I can't help... Read more
Forum topic
Hi folks,
AIA COTE National is looking for Techincal Reviewers for the 2025 awards. Interested, or know someone who might be? Sign up here: https://form.jotform.com/231175886103153
Thanks!
Forum topic
Have any of you relied on Green Badger for LEED documentation on projects?
I am familiar with the tool and know Tommy from my time in Atlanta, but have not used it on a construction project.
Have you found value? Thoughts?
Either way, they publish a pretty nifty "LEED v4 Construction Tool Kit" that may be useful for your... Read more
Forum topic
Following up on one of our conversations on the vision vacuum and sustainability beyond certifications, I would like to help facilitate an offline conversation with anyone working within their firm to use the AIA COTE measures as a guiding framework in their firms/projects. Attached are my slides on my first pass at thinking about this at Page... Read more
Forum topic
Hello,
We’re looking for Design Energy Code Equivalents for Chinese commercial energy codes. Do any of you have any good sources? I’ve only found data comparing ASHRAE 90.1 2013 to the Chinese Code at that time. We understand the Chinese code require a 65-75% energy savings over the baseline but don’t have good information for defining... Read more
Peer Network Event
Forum topic
Has anyone completed an LCA for an engineering structures lab, particularly one that has a strong wall and strong floor?
Forum topic
Join your peers and BuildingGreen February 22–26, 2021 for an all you can eat buffet week of networking, problem solving, and connecting with sustainability leaders within your industry and across the Peer Networks! During this week we will create a space for you to offer and receive support, exchange ideas and resources, and become stronger,... Read more
Forum topic
Asking for a colleague:
"Have you ever had a large number of fire retardant tarps used to temporarily enclose a building during construction? Do you know of any solutions for recycling/reusing them or another product that doesn't use toxic fire-retardants that meets the performance criteria?"
I think we've all seen poly or fabric... Read more
Forum topic
All,
Can anyone suggest a product for the following situation. We are looking to insulate existing aluminum eterior column covers that have a three inch air gap. The issue is there is no way to remove the covers without destroying them. we would like to cut small holes, pump in the insulation and then cap the holes. Can anyone... Read more
Reports, Courses, Study Guides, Live Webinars
A site license allows your entire organization to access and share the report, and to keep a copy in your library. The site license does not allow multiple users to earn CEUs. If multiple individuals in your organization would like to earn CEUs from this report, please ... Read more
Forum topic
I'm sure most (if not everyone) is aware that LEEDv5 is under public review until May 20, 2024. I know I need to make time to flip through it, review, and comment, but I'm having a heckuva time protecting the time in my calendar to do that. Anyone interested in joining me for a 60 - 90 minute meeting to do this together as an accountability... Read more
Product Guide
The opportunity for water savings from installing efficient toilets, and from toilet replacement, is significant. In addition to improvements to the traditional gravity system, pressure- and vacuum-assisted flushing systems are available that offer superior performance—albeit often with some increase in flushing noise.
Cautions Certain... Read moreForum topic
Hi Fellow SDLers: I'm writing to share intel about two recent climate change articles that provide links to some great new resources:
1. From the AIA Trust: An excellent article in this month's AIA Trust Newsletter on "Climate Impact on Professional Liability." This includes links to some useful resources including the new AIA Hazard and... Read more
Forum topic
First, there was Energy Use reductions
Then there was embodied carbon
Soon it will be refrigerant use/leakage calculations
…and much more
As coordinators and leaders of project teams, what does this look like for the practicing architect and our collaborators?
I have no idea. BUT I’m guessing someone is... Read more
Quiz
Welcome to the quiz portion of No More Red Lines: Undoing Our Legacy of Urban Segregation.
Learning Objectives
Upon completing this course, participants will be able to: