Hey SDL,

I'm curious if anybody out there has developed specification language requiring a certain level of airtightness (as assessed via one or a series of blower door tests) for a commercial project when it is not going for a Passive House certification and a blower door test is not required by code--basically, something in the... Read more

Forum topic

We have an MEP engineer that is calculating peak loads at about 6 times passive house levels on a large commercial building that is at or near passive house levels of insulation and air infiltration. We suspect one reason is that he is figuring a 50% efficiency level for the ERV. We are showing him ERV systems with 80-90% efficiency, but they... Read more

Reports, Courses, Study Guides, Live Webinars

A site license allows your entire organization to access and share the report, and to keep a copy in your library. The site license does not allow multiple users to access the CEU quiz. If multiple individuals in your organization would like to access the CEU quiz from this report, please purchase individual copies. ​

A seal of... Read more

Forum topic

Good morning, All,

Just a bit of news this morning.  My family and I are moving back out west!  I am continuing in my current role with EwingCole, but will be doing so from Portland, Oregon.  Although North Carolina has a been a wonderful place for us for the past 13 years, it is time to be close to family in the northwest and southwest... Read more

Forum topic

Dear SDL: Thanks to all who have already given their support to the AIA Resolution on Urgent and Sustained Climate Action. We're into the final push of getting out the vote to pass the resolution next Wednesday, June 5th afternoon in Las Vegas. This requires 2/3s of the voting delegates to pass. So we're asking anyone who 1) is attending as a... Read more

Forum topic

Hey all - sorry I won't be able to join our call today. I had a client request an emergency meeting today (boo) because corporate mandated that they eliminate fossil fuel use from all their buildings (yay!) by 2025 and they've got a project underway that needs to pivot quickly. 

Had I been able to join, I wanted to share this in case... Read more

Forum topic

hi all! I'm almost at the finish line with this year's 2030 reporting...whew. I'm running into an issue that I wanted to throw out to this group, regarding the zero tool and national average baselines. Hoping some of y'all who manage your firm's 2030 data, or are just more familiar with CBECS and related data, have some insight / experience to... Read more

Forum topic

All,

I've probably spoken to a few of you over the phone, but I wanted to make sure all of you know that we are hosting a 4 part webinar series on our Tally LCA software, kicking off tomorrow 10/10. We just released the new of Tally version and ended up doing far more development work than initially anticipated, in no small part due to... Read more

Forum topic

Here are the links I mentioned at today's meeting:

Timeline:
https://docs.google.com/presentation/d/1RlN4t23uvBtxEzp4QuyqL-w5bqmE4P90...

BG Contacts and Responsibilities:
https://docs.google.com/document/d/1MWYuAEitjk7Zpc8KUNf1LwG3-5wK6sIlgwro...

BITuser Contacts and Responsibilities:
https://docs.google.... Read more

Forum topic

Hello,

We’re looking for Design Energy Code Equivalents for Chinese commercial energy codes. Do any of you have  any good sources? I’ve only found data comparing ASHRAE 90.1 2013 to the Chinese Code at that time. We understand the Chinese code require a 65-75% energy savings over the baseline but don’t have good information for defining... Read more

Forum topic

Hello Everyone,

On September 9th a regional cross-network group gathered for the first in-person Peer Networks event since the beginning of the pandemic. All Peer Networks were represented at this Boston Region Mini-Summit! With this first one in the books, BuildingGreen is hopeful for paving the way to future regional events across the... Read more

Forum topic

Hey Peer Network! Curious, if we can crowd-source a solution here for the pervious pavers at our Omaha office (climate zone 5A). Apparently over the years we've tried to add different kinds of fill here (gravel) but it keeps... disappearing. Any recommendations with either a replacement product or fill item? 

Forum topic

Hello Everyone,

I'm looking for projects in Chicago that are exemplary in at least one of the following topics: Biophilia, Sustainability, Resilience, or Well-being. I know there is overlap in these topics but we're doing an internal design exercise and are looking at how these different ideas relate and are articulated in buildings. We'... Read more

Basic page

Last updated October 26th, 2022

What this policy covers

BuildingGreen, Inc. values your privacy. This notice describes what information we collect and how we use it.

To Users Resident in the European Economic Area:  This Privacy Policy will govern use of your personal information if you choose to use any... Read more

Forum topic

On a large sports project, we worked with the structural engineer to spec low carbon / high SCM concrete mixes. Much of the floor area will be sealed and polished concrete, and a concrete sub is pushing back on the SCMs saying they should not be above 20% (with a preference for 0%) for the polish to finish properly, per the manufacturer. Anyone... Read more

Author

Ace Brockwell

Forum topic

Hi Everyone!  About ten days ago, Megan Zack posted a note announcing her new role as Chief Sustainability Officer at Wight & Company. (Yay!)  I'm so delighted that she will be stepping into this leadership role at Wight to shepard the firm in the next chapter of their journey in sustainability. 

I wanted to take a moment to say... Read more