Forum topic
What thoughts do you have? What have others said that you feel we want to capture?
The Vision Vacuum: What’s driving environmental and social progress in architecture today? What should be driving it, and where should we be going?
Forum topic
Thanks to SERA especially David, Kira and Clark for an inspirational conversation with Paul Hawken about his latest book. I know I needed a positive perspective! Then I found this great "Regeneration Anthem" song and had to share.
https://regeneration.org/news/210915-we-can-change-world-regeneration-an...
Happy Fall to all.
... Read moreForum topic
Hey SDL,
I'm curious if anybody out there has developed specification language requiring a certain level of airtightness (as assessed via one or a series of blower door tests) for a commercial project when it is not going for a Passive House certification and a blower door test is not required by code--basically, something in the... Read more
Sales page
Can furniture be hazardous? You bet it can…
From flame retardants in foam cushions to unnecessary stain and dirt repellents on upholstery materials, everyday... Read more
Basic page
The BuildingGreen/GreenStep exam prep materials are... Read more
Forum topic
Hello Folks,
What is your experience with successes and failures in the design process? As a starting point I have listed my Top 5 for success, and my Top 5 for failure. We'd love to see your reactions and look forward to the discussion when we all meet next week at our monthly check-in.
Top 5 reasons for when integrative design... Read more
Forum topic
The position for my replacement has been posted. Please share within your networks. Thanks!
http://www.fxcollaborative.com/profile/9/careers/
Forum topic
Hi All,
Has anyone dug into ASHRAE 2016 as part of the new v4.1 requirements or as codes start to adopt it? I recently presented on this and thought I should check my math to make sure I'm understanding and communicating this correctly.
My understanding is that there is a new reference baseline, that is essentially the ASHRAE 2004... Read more
Reports, Courses, Study Guides, Live Webinars
A site license allows your entire organization to access and share the report, and to keep a copy in your library. The site license does not allow multiple users to earn CEUs. If multiple individuals in your organization would like to earn CEUs from this report, please ... Read more
Forum topic
We are having trouble sourcing a LEED compliant wallcovering adhesive. We specified Roman Pro-880 which is low VOC but doesn't have sufficient back up for TVOCs. Have you had success with other products?
Forum topic
We have an MEP engineer that is calculating peak loads at about 6 times passive house levels on a large commercial building that is at or near passive house levels of insulation and air infiltration. We suspect one reason is that he is figuring a 50% efficiency level for the ERV. We are showing him ERV systems with 80-90% efficiency, but they... Read more
Forum topic
Hi all,
We have a newly constructed, core/shell project having some hot water issues in the core restrooms.
There is a 0.35 Toto lav installed throughout. The hot water heaters are adjacent on each floor, located in the janitor closets. We did the math, and there could be a gallon of water standing and cooling in the pipe between... Read more
Author
For more than 30 years, Alex Wilson has been the most trusted voice on energy efficiency and environmentally responsible design and construction. Since launching Environmental Building News (EBN) in 1992, he’s built a reputation, resources, and staff to provide the foundation for BuildingGreen, a consulting and information company... Read more
Forum topic
Hi Everyone,
Has anyone had success in finding organizations or programs that will recycle the hard hats? We are looking into options for recycling our expired hard hats that can no longer be used. Ideally, we would want to use a company with facilities across the country but we are open to any suggestions or ideas you all may have.... Read more
Forum topic
Hey Peer Network! Curious, if we can crowd-source a solution here for the pervious pavers at our Omaha office (climate zone 5A). Apparently over the years we've tried to add different kinds of fill here (gravel) but it keeps... disappearing. Any recommendations with either a replacement product or fill item?
Quiz
Welcome to the quiz portion of Rebuilding for Resilience in the Face of Natural Disasters!
IMPORTANT: This quiz covers three related articles within this topic.
Learning Objectives
Upon completing this course, participants will be able to:
Forum topic
Here's the Core Purpose for this group that came out of the Inaugural Summit.