Here is a fundamental question regarding measuring operational carbon emissions that I'm sure many of you can clarify for me:  Let's say you are considering design options and you want to know the relative contribution of GWP of adding an additional inch of continuous insulation to the building envelope.  The GWP from embodied carbon will... Read more

Forum topic

Looking for an example or case study for a building utilizing a radiant heating/cooling in climate zone 4a. General use type is office with some public assembly spaces, total of 85,000 sf.

As usual, everyone, especially mechanical engineer, is terrified by the thought of "condensation." So far, I read a DGWW case study, "Energy... Read more

Forum topic

Hi all,

Thanks again to those who presented at the AIA Show & Tell! Here are the slides for some of the fascinating presentations we saw. Please do not share the slides outside of the networks unless they are marked “PUBLIC.”

There may be more to come; if you presented but did not yet provide permission for your slides to be... Read more

Quiz

Welcome to the quiz portion of The Death and Rebirth of DC Power. 

Learning Objectives
Upon completing this course, participants will be able to:


Explain when and how to integrate DC power into buildings, and the benefits of doing so.

Understand the history and background of AC and DC power in the U.S.

... Read more

Forum topic

We have a client who is asking us to design a roughly 10 ksf Wellness Center for PHIUS 2021 certification.  The program includes several high density assembly type spaces - roughly 300 person peak occupant load for the building.  The Criteria Calculator that the architect showed us puts the building peak cooling load at 4 BTUH/sf (3000 sf/ton... Read more

Forum topic

Hello all, 

Any Fitwel experts out there? I have a 30,000 sf boutique hotel + spa client who would like to certify under the Fitwel rating system but Fitwel folks are telling me that no scorecard is currently available to hotel clients (can't use mulit-tenant or resi, that a hotel scorecard is under development). Has anyone used Fitwel... Read more

Forum topic

Hello! 

We have several projects that are either pending ILFI Zero Carbon certification or the owner is planning to purchase offsets to cover construction emissions. Thus far, I have not considered this in our corporate footprint reporting. However, we are including A5 emissions whenever feasible and multiplying that performance over the... Read more

Forum topic

I'm working with a project team that is looking into bird control options to prevent nesting/roosting/pooping on the scrim that is designed to scrim their building's facade.  They are looking at electrified tape, repellents, laser systems, etc -- Options that don't dramatically impact the building design.  The products they're looking at claim... Read more

Forum topic

Hi friends,

We recently tracked our water consumption on site during the structural demolition of some existing reinforced concrete buildings.  The new OSHA silica regulations required us to keep dust to virtually zero, so we had a bunch of mist cannons and water hoses pumping water around the clock.  We consumed ~855,000 gallons in a... Read more

Forum topic

Hi All,

My team member is leaving Webcor, and unfortunately that means we have to fill her big shoes with someone new! I thought I'd reachout here and see if you know anyone of high caliber looking for a Sustainability Manager position? Someone with LEED PM experience preferred, and a bit more technical background with MEP/ZNE ideally... Read more

Quiz

Sustainability leadership has requested that you take this quiz to help assess sustainability literacy across the firm. Your own results will be presented to you at the end of the quiz but will not be shared with anyone else. Only aggregated, anonymized results will be available to others.

Please don’t do research to inform your... Read more

Product Guide

CEUs are available for reading all the building-envelope product guides and primer. Click here to learn more and take the quiz.

Stick-framed walls are labor intensive and have to be sealed and insulated in the field, where conditions are not ideal; this can lead to poor thermal performance.

BuildingGreen-Approved Structural... Read more

Forum topic

Hi all,

We have a project in New Orleans that needs to meet the GSA Inflation Reduction Act (IRA) requirements and submit EPDs. For our concrete, there is only one manufacturer that meets the requirements and is more than 50 miles away (according to EC3). Does anyone have tips on attempting to talk to local concrete manufacturers about... Read more

Forum topic

Hi SDLs,

Do you have design experience or a unique perspective on trying to include ungendered multiuser restrooms in AEC projects? We want to hear from you.

To prepare for a co-creative workshop as a part of the Environmental Design Research Association's 53rd Annual Conference, "Health in All Places," B. Sanborn, Nicole DeNamur... Read more

Team Group

Forum topic

The results from the "CogFx" study are compelling, showing that people in environments with low VOCs and low ambient CO2 levels score higher on tests of cognitive function.  Specifically, they show that providing 40cfm of outdoor air per (actual live) occupant results in significantly higher scores than even the "Enhanced Ventilation" scheme... Read more

Forum topic

Hello Green Gurus,

Here's another Peer Networks Webinar for September, Prospects for Sustainable Buildings in Congress. We hope you will join us!

Reminder: This webinar is for Peer Networks members only.

I'm waiting to confirm with the presenters whether this will be recorded. Watch this space for updates!

Register... Read more