Forum topic
Hi All!
We have had a few multi-family projects consider this single package vertical unit with integrated ERV, but we haven't pulled the trigger for fear of the unknown. Our local engineers aren't sure how it actually performs and worry it may not meet code requirements for separation between exhaust and intake. Has anyone else used... Read more
Forum topic
Hi! Just saw this White House press release stating that federal suppliers will need to report on scope 1 & 2, and relevant scope 3 emissions and climate-related financial risks as well as set science-based emission reduction targets. The cutoff for disclosure requirements is $50m in federal contracts. Curious whether this affects any... Read more
Forum topic
Friends, I reviewed the firm's 2019 AIA 2030 data with a Principal, having organized the data in such a way that we could manipulate it. I included the average EUI and weighted EUI, since the latter gives a truer picture of where we are as a studio. In the past, the assumption was we would raise all boats with efforts to improve our practice in... Read more
Forum topic
Greetings, all:
AIA COTE Advocacy is working with AIA Gov't Affairs to assemble a directory of COTE-friendly AIA Members who are passionate about environmental advocacy and VOTERS in targeted congressional districts. We are organizing in-district meetings after the mid-term elections focused on the members of the Senate Energy &... Read more
Forum topic
We are working on a tenant improvement and want to determine the embodied carbon on bookshelves, product display cases, and desks. Initially finding that Tally is not reading furniture, casework, or fixture families. Are there any tips and tricks you have found to be successful for modeling or defining FFE items in Revit and quantifying... Read more
Forum topic
All -
I know many of your firms do landscape design, and I wanted to make sure you were aware of a new and pretty impressive conceptual calculator to estimate the carbon impacts (emissions and sinks) of landscape design. Developed by Pamela Conrad of CMG Landscape with grant support, Atelier 10 and an app developer, the tool allows you... Read more
Product Guide
Chillers are part of larger systems that provide cooling in large commercial buildings.
BuildingGreen-Approved Water Chillers
Because there isn't a single relevant efficiency standard for chillers, approved products use innovations such as magnetic bearings, variable frequency drives, or other technologies that significantly... Read more
Forum topic
Hey, everyone! Reaching out to share about the currently-under-development IEA Annex 89: Ways to Implement Net-zero Whole Life Carbon Buildings. The current committee is really the who's who of building LCA in Europe, but it does seem like it suffers from a lack of North American representation. The one North American on the committee, in fact... Read more
Forum topic
Greetings Gurus!
Please sign up and spread the word (even if you can't attend, sign up to get follow up info!)
This is one of a series of Hackathons to crowdsource alternative design details that are intentionally meant for disassembly! The outputs are meant for public consumption so that anyone who doesn't have time (that's... Read more
Forum topic
We are looking into different building skin materials from including GFRC and FRP (amongst others) as alternatives to precast. I remember years ago (when I was at LAS) we had retrofitted a Federal Courthouse with FRP for blast resistance. I kind of remember that at the time it had some pretty high offgassing concerns. I haven't been able to... Read more
Quiz
Welcome to the quiz portion of How Buildings Fail Their Users!
Learning Objectives
Upon completing this course, participants will be able to:
Explain the importance of finding common ground between a client’s project goals and the project team’s sustainability building goals for successful projects that incorporate... Read more
Forum topic
Received answers from below questions from NIST Andy Persily
1. Is there a preferred bookends range of CO2 for both “optimal” energy and human performances?
Andy: No
2.Is the ASHRAE ventilation of 1000-1200 ppm average, probably not based on performance, suggesting current ventilation rate is sub-optimal with cognitive... Read more
Quiz
Welcome to the quiz portion of Rethinking the All-Glass Building.
Learning Objectives
Upon completing this course, participants will be able to:
1. Describe eight reasons all-glass buildings are so popular in architecture today.
2. List the four elements Arup examined in their modeling of the effect of... Read more
Forum topic
Save the Date: If you'll be in DC for AIA's Conference on Architecture or just happen to live nearby, hold 6:00–8:30 pm on Wednesday, June 5 for this event.
6:00–7:00 Reception 7:00–8:30 Show & TellWe have partners! This event will be hosted by ZGF Architects (on their lovely rooftop patio) in collaboration with US Architects... Read more
Forum topic
We all know the climates are shifting, and the ASHRAE standard that gets invoked for energy codes is shifting along with them--though not in perfect sync. Louisiana is leaping from ASHRAE 90.1-2007 energy code to 2021 IECC (boom!). The 2021 IECC as published uses relatively old climate maps; for Louisiana, at least, the same as the 90.1-2007... Read more