Forum topic
Hello All!
We are using TallyCat to extract quantities from our REVIT Model, and bring them over to EC3 to get a model GWP (focusing on material categories required to evaluate ILFI Zero Carbon certification). There are a number of questions that are popping up!!
I am sure there are others trying the same thing, yes... maybe?! ... Read more
Forum topic
Hi All,
I wanted to share an exciting opportinity with this esteemed group: Placetailor is seeking out a Mechanical Engineer to add to their growing team. They are located in Boston, MA and focus on Passive House, Low-energy Design, and they have for two years running meet the tenets of the AIA 2030 Commitment! This is an exciting place... Read more
Forum topic
So I was testing assigning a BIT Expert to a Best Practice and I am having trouble getting the profile image to appear.
When I upload a profile picture, it appears on the standard profile page from "My Account" but when I navigate to the BIT Best Practice 01, the image does not show and it takes me to another profile page that does... Read more
Quiz
Welcome to the quiz portion of Why High-Performance Assemblies and Why Now? (recorded webcast)
Learning Objectives
Upon completing this course, participants will be able to:
1. Understand how water moves on and through buildings.
2. Describe the details of continuous air, water, and thermal barriers and... Read more
Forum topic
I'm hoping someone knows the anser to this question. For the LEED ND certification the minimum requirement is "The LEED project should contain at least two habitable buildings and be no larger than 1500 acres." Does habitable mean buildings with dwelling units?
Author
Valentina works on the UX/UI design and front-end of the BuildingGreen and LEEDuser websites. With over 10 years’ experience focused on websites usability, she develops prototypes and cross-browser web interfaces as part of the WebDev team. She also collaborates closely with marketing and editorial to create any other visual design project for... Read more
Forum topic
Hi Gurus!
I'm desperately seeking any case studies (past/currently on the boards) of labs that have been designed without natural gas infrastructure (the topic I have to debate is about commercial spec labs but any lab case study, wet or dry, is welcomed). This is for a development authority that will be setting guidelines for new... Read more
Forum topic
Hi, this is a somewhat niche/specific question - we are working on an all-electric school (middle and high school) that includes a chemistry lab. The lab was going to have portable sources for flame experiments, but there is concern that the portable sources would be unsafe for middle school students, so they are asking for a hard-pipe natural... Read more
Basic page
FILTER BY NETWORK
All (Green Gurus) Sustainable Design Leaders Sustainable Design Leaders - Small Firm Sustainable Construction Leaders Sustainable MEP Leaders Sustainable Advising LeadersFILTER BY REGION
... Read moreQuiz
Welcome to the quiz portion of Integrated Design Meets the Real World.
Learning Objectives
Upon completing this course, participants will be able to:
1. Define the integrated design process and describe what makes it different from the conventional design process.
2. Describe the charrette process and list... Read more
Forum topic
Hi All -
I'm wondering if any of our SDL people have a project case study on designing for deconstruction that they'd like to present on? I know there are a lot of conversations that we should be designing for deconstruction but has anyone done a focused project? Thank you for any input you might have.
Forum topic
I was wondering if any design or contractor friend here can kindly share the carbon emission factor of excavation during construction.
I found a paper that provides energy use rate per cubic meter and associated carbon emission in kgCO2 for different phase of construction such as excavation earth work, pouring and lifting concrete,... Read more
Forum topic
Is anyone aware of research or guidance that has looked at VOC’s from roofing products and ventilation intakes? I’ve done some searching, and focus is mainly on managing the construction process to reduce installer exposure.
Thanks for any help!
Tate
Product Guide
Typically made from petrochemicals, carpet and its adhesives can offgas. It is also a challenge to recycle them, increasing the chances that it will be incinerated or disposed of in a landfill. Because carpet has a limited lifespan, its life-cycle performance is key.
BuildingGreen recommends modular carpet that demonstrates lower life-... Read more
Forum topic
Hi All
I'm wondering if any of you know how to track the GWP for materials that do not have an EPD? I'm trying to do a carbon comparison on batteries but neither one has an EPD that I can find. Thanks for any guidance you may have.
Forum topic
Happy 2021 Green Gurus,
BuildingGreen has some New Years news to share with you all!
Announcing an addition to the Peer Networks family, we are excited to be launching the Sustainable Community Design Leaders (SCDL) Peer Network!
The SCLD peers are planners, architects, landscape architects, and other professionals at... Read more