BuildingGreen Report

Forum topic

Hello Everyone!

Please mark your calendars and stay tuned for more information regarding an All Peer Networks 2020 Summit Season Closing August 10th, 3-5pm ET (Noon-2pm PT).

Register HERE to get it on your calendar! The staff at BuildingGreen are looking forward to planning a fun and engaging cross-network event focused on this... Read more

Campus-wide Group

Forum topic

Hello all!

I'm new to the group, and so excited to be here. Two part question here (as we think about processes and new year goals).

I am at a smallish firm (20 people) in Boston helping to reform our processes to enable even those that are not steeped in sustainability at a daily level to be comfortable looking for opporutunities... Read more

Forum topic

Dear SDL: Thanks to all who have already given their support to the AIA Resolution on Urgent and Sustained Climate Action. We're into the final push of getting out the vote to pass the resolution next Wednesday, June 5th afternoon in Las Vegas. This requires 2/3s of the voting delegates to pass. So we're asking anyone who 1) is attending as a... Read more

Forum topic

Hello - 

I am looking for the recording and the PDF/ slides that were shared 3/6 for the project process share-out/ 5 min presentations. It was super inspiring and I would like to refresh my memory of some of what was shared. Thank you!

–
Alison Nash 
AIA, LEED AP ID+C, CPHC, WELL AP
Associate | Sustainability... Read more

Forum topic

Hey SDL,

I'm curious if anybody out there has developed specification language requiring a certain level of airtightness (as assessed via one or a series of blower door tests) for a commercial project when it is not going for a Passive House certification and a blower door test is not required by code--basically, something in the... Read more

Product Guide

Fluid-applied flooring (FAF), or resinous flooring, is made from various hazardous chemicals that can be released into the building, especially during application.

BuildingGreen-Approved Flooring

BuildingGreen selects FAF that meets CARB emissions standards AND either contains recycled content or offers other positive... Read more

Forum topic

If only a few of the Best Practices will have checklists, which will be included under the "Implementation Toolkit" tab, I'm thinking we can simplify them (compared with LEEDuser).

I've attached a screenshot of a LEEDuser checklist. But I don't think BITuser will need the four types of icons, and the legend will take up more space than... Read more

Forum topic

We have an MEP engineer that is calculating peak loads at about 6 times passive house levels on a large commercial building that is at or near passive house levels of insulation and air infiltration. We suspect one reason is that he is figuring a 50% efficiency level for the ERV. We are showing him ERV systems with 80-90% efficiency, but they... Read more

Forum topic

Hi All,

Has anyone dug into ASHRAE 2016 as part of the new v4.1 requirements or as codes start to adopt it? I recently presented on this and thought I should check my math to make sure I'm understanding and communicating this correctly.

My understanding is that there is a new reference baseline, that is essentially the ASHRAE 2004... Read more

Forum topic

***Cross-posting this from SCL Group***

Last year I was approached by Green Advantage, remember them from like 2005? There has been a LEED innovation credit for as long as I can remember.

Has anyone seen employed Green Advantage recently? Is anyone asking for it?

Do you see value in GCs/CMs/trades having this training... Read more

Quiz

Welcome to the quiz portion of What Makes the Building Envelope Green? BuildingGreen’s Guide to Thermal & Moisture Protection Products.

Learning Objectives
Upon completing this course, participants will be able to:


 

1. Describe attributes of the greenest building envelope products.
2. Explain how to... Read more

Forum topic

Hello,

We’re looking for Design Energy Code Equivalents for Chinese commercial energy codes. Do any of you have  any good sources? I’ve only found data comparing ASHRAE 90.1 2013 to the Chinese Code at that time. We understand the Chinese code require a 65-75% energy savings over the baseline but don’t have good information for defining... Read more

Forum topic

It is with the greatest pleasure that I announce to this esteemed group the recognition of our very own and much-loved leader Nadav Malin as an Honorary AIA member. AIA COTE had the honor to serve as Nadav's sponsor and we are pleased and delighted with this outcome (but not surprised of course.) For the record, "The AIA recognizes the notable... Read more

Forum topic

We are having trouble sourcing a LEED compliant wallcovering adhesive. We specified Roman Pro-880 which is low VOC but doesn't have sufficient back up for TVOCs. Have you had success with other products?