Hi all,

We've had a number of clients in the states surrounding Texas that have been hit with really high natural gas bills for February. Some as high as $2.00+/therm. Many are healthcare facilities.  Has anyone seen any federal, state, or utility relief programs that are assisting customers with these bills?

Thanks, 

Adam... Read more

Forum topic

Hi folks,

You may have seen this posted to the Green Gurus forum. Paula got some good responses from architects and engineers, but not so much from GCs so she asked me to follow up and post it here. Please reach out to her if you're willing to be included in these articles/reports. Thanks!

Hi! I’m working on two reports about... Read more

Forum topic

Has anyone here had success in comparing life cycle impacts for different window system options? We have been trying to compare different options but have only been able to source one expired EPD for an actual window (frame + glazing). Is the typical approach to separately compare glass and framing options? Are we missing something or is there... Read more

Forum topic

Team,

After talking to UL today, I thought it will be good for them to do a presentation on what they see in embodied energy/carbon road map of MEP equipment can be like.

Should we schedule them for a 30 minutes presentation in the next call?

Best,

LL

Forum topic

If you have been wondering about the Contractor Commitment, we have an update for you!

Several weeks ago, the subgroup leaders and the Steering Committee members gathered to agree on a basic structure for the Commitment. The idea was to align the basic expectations around issues like how many tiers there would be, what would be disclosed... Read more

Forum topic

I'm happy to announce the Call for Presenters for this year's Gulf Coast Green, taking place in Houston May 17th.  Our theme is Crossroads: Inclusive Exchange.  We are especially seeking presentations that focus on how design can engage the community and foster social bonds and social justice.  I’m sure many of you have work that is relevant,... Read more

Forum topic

Dear Colleagues,

I proposed CarbonCure for a project and the structural engineer in the meeting was opposed to it. He later sent me detailed reasoning by email. I have not used this technology and would like to hear other more experienced opinions on the technology. The project we are working on is well integrated with climate, 99% sDA,... Read more

Reports, Courses, Study Guides, Live Webinars

Concrete and other cementitious materials have both environmental advantages and disadvantages. As builders and designers, should we be looking for alternatives or embracing concrete over competing materials?

This special report takes a look at how these materials are made, presents the key environmental considerations relating to their... Read more

Product Guide

Discarded tires are an environmental disaster, and finding a beneficial use for them is a high priority.

BuildingGreen-Approved Resilient Flooring

BuildingGreen does not approve any flooring product that is made with tire-derived rubber, though some products may be appropriate for exterior use.

Environmental and Health Impacts of... Read more

Peer Network Event

Forum topic

Hi All,

I'm working on a LEED for Schools project under 2009, and received some amorphous comments back about our Mold Prevention Plan. We used the LEEDuser template as a guide, while also referencing the EPA document the credit is based around, but the reviewers feel we haven't provided proper metrics. The EPA plan is something like... Read more

Forum topic

Hi there Hive Mind! Hope everyone's doing well and staying cool in the heatwave all over.

An engineer on one of my projects reached out about contact switches for operable windows that are empowered to shut down the associated FCU in dormitory bedrooms when the window is open. This functionality allows the FCU to run at something like... Read more

Product Guide

Pint-flush and non-water urinals can save tens of thousands of gallons of potable water per year. A single non-water-using urinal can save more than 10,000 gallons of water per year compared with the U.S. EPA standard of 1.0 gallon per flush (gpf).

When older 3.0 gpf urinals are replaced, the savings can be as great as 50,000 gallons... Read more

Author

Katherine keeps BuildingGreen’s physical and digital spaces running smoothly. A graduate with honors from the University of Iowa, Katherine has a background in filmmaking and administration. She lives in southeastern Vermont with her partner and enjoys hiking, board games, writing, and cats.

Forum topic

Hello Green Gurus,

Here is the information for November's Peer Networks Webinar, Learning and Applying Evidence, Rosetta Stone: A Translational Tool for Research-Informed Practice. We hope you will join us!

Register HERE

Learning and Applying Evidence, Rosetta Stone: A Translational Tool for Research-Informed Practice... Read more

Forum topic

Hi all, we are embarking on an effort to standardize our LCA process in order to maintain a firmwide database of embodied carbon intensity from which we can create internal baselines and targets. I was wondering how other offices are setting boundaries for their LCA efforts. Below is our starting point. Most LCA will be conducted using Tally.... Read more

Forum topic

We have several projects that are small enough that we don't hire consultants to run energy models. I just received permission to do some training so that I can run these models myself. I am looking at doing this training on eQuest:

https://www.udemy.com/course/equest-energy-modelling-detailedtraining/?c...

I am thinking it would... Read more

Forum topic

Apologize in advance if this has been posted before but we are trying to get manufacturers of stage curtains to give documentation that proves that the product does not have halogenated fire retardants. Manufacturers say they don't have them or concentrations are limited to 100ppm but they don't seem to have documentation to provide for it.... Read more