Forum topic
Does anyone have a Passive House detailing resource recommendation? Something that is applicable to wood over podium and/or metal framing construction? I have the book below but looking for something more applicable.
Passive House Details: Solutions for High-Performance Design 1st Edition
by Donald B. Corner (Author), Jan C.... Read more
Product Guide
CEUs are available for reading our entire plumbing guide. Click here to learn more and take the quiz.
Excess heat generated by air conditioners, refrigerators, boilers, and water flowing through pipes typically goes unused.
BuildingGreen-Approved Water Heat Exchangers
BuildingGreen lists desuperheating technologies and... Read more
Forum topic
Hello small firm Sustainable Design Leaders!
We are cancelling our call next week that had been scheduled for 2/13 @ 1pm. That same day, Thursday, BuildingGreen is hosting an all Peer Networks WEBINAR. Please consider participating with the sustainability leaders from all peer networks: Design Leaders, Construction Leaders, MEP Leaders... Read more
Forum topic
Huge congratulations to everyone involved with a Top Ten winner this year!
In a rare feat--Leddy Maytum Stacy got two!
Also P+W, Lake|Flato with Cooper Cary, WRNS, SOM, Olsen Kundig, KieranTimberlake, DLR--nice work! (And who is Studio27?)
Here's James Wilson's take on what's special about each winning project.
... Read more
Forum topic
Hi All, this is primarily directed at our Sustainable MEP folks, but please anyone with insight feel free to weigh in.
I am increasingly seeing designs and specifications asking for Passive House levels of airtightness as verified by blower door testing, but with traditional ventilation system designs.
To me, Passive House US has... Read more
Forum topic
Hi everyone,
Just a reminder to please fill out the SCL 2024 Events Attendance Poll by the end of next Monday, December 18th. Thank you so much to those who have filled it out already! :)
-Amanda
Forum topic
Friends,
We put a lot of effort into air tightness design, detailing, and construction administration, often including 6-sided mockup and parital or whole-building blower-door testing. For commercial buildings, these tests measure air leakage in cfm/sf at 1.57 psf (75pa).
I came across this research paper several years ago, but... Read more
Forum topic
Have any of you heard of anyone ever using phase change material (PCM) "movable partitions" as a resiliency strategy to mitigate indoor overheating during a heat wave in passive buildings? You'd keep them stored in a basement or cool room, and deploy them into habitable spaces during the heat wave to keep the space cooler than the exterior... Read more
Forum topic
Hi folks,
Wondering if this group has insights about the low-embodied carbon product "Vertua" from Cemex, which appears to be a proprietary concrete product launched in 2020.
Our client wants to use CarbonCure; but our likely concrete sub is saying Cemex (where they typically source their concrete) offers an alternative called... Read more
Forum topic
Does anyone have a good recommendation for getting started with energy modeling with future weather files? We use a combination of Sefaira and Climate Studio, but open to suggestions. Even just links on how to approach this for making good recommendations to clients. Thanks in advance.
Forum topic
Hi folks,
Oregon’s ZERO Coalition is looking for responses to the question below on local policy for electrification, and I thought tapping this group would be helpful.
Are you aware of any local governments outside of Oregon that are promoting or enforcing electrification?
Berkley, CA is one example that as of Jan 1, 2020... Read moreForum topic
Peeps, in case you haven't gotten the email blasts--the AIA wants YOU! Now is the time to throw your hat into the ring for volunteering on the following committees/groups:
2030 Working Group (with Keith Hempel! and Ashley Mulhall!) A&D Materials Pledge Working Group (build on the amazing work Lona Rerick and others have been doing for... Read moreForum topic
Dear all,
For a specific existing building application, we are looking for a half inch insulating glazing unit, preferably with low-e coating. Based on my research, 5/8" seems to be doable (1/8" glass + 3/8" air gap + 1/8" glass) but I'm yet to find a viable 1/2" solution. Have you come across any on your projects? Thanks for your... Read more
Forum topic
Hi All,
It's been a great week to get the message out about the importance of sustainability in our work, and this group brings such a rich and nuanced perspective to the table. I'm asking, if you published something for earth day this week for external consumption, could you share that here? I'm curious to see if there are common themes... Read more
Quiz
Welcome to the quiz portion of Ten Strategies for Growth in a Recession.
Learning Objectives
Upon completing this course, participants will be able to:
1. Understand the importance of diversifying.
2. Restate the benefits to doing energy-modeling analysis very early in the design process.
3. Discuss how... Read more