Forum topic
Team,
Many of you saw this from BlackRock.
https://www.blackrock.com/corporate/investor-relations/larry-fink-ceo-letter
SOM, starting with London office, is drafting a letter to our MEP consultants, demanding and holding them accountable for climate change as a preference on consultants selection.
Best,
LL
Forum topic
Hello- If you use Procore....
Are your jobs using a template to conduct and create "reports" of their IAQ inspections? Did you set it up in forms or inspections? Would you mind sharing an example template with me? I know Green Badger has a great app to do this, which we use. We would use inspections in Procore for jobs that are not using... Read more
Quiz
Welcome to the quiz portion of The Hidden Science of High-Performance Building Assemblies.
Learning Objectives
Upon completing this course, participants will be able to:
1. Define hygrothermal pressure and explain what it requires of water, air, and thermal barriers in high-performance assemblies.
2. Explain... Read more
Forum topic
We are having trouble sourcing a LEED compliant wallcovering adhesive. We specified Roman Pro-880 which is low VOC but doesn't have sufficient back up for TVOCs. Have you had success with other products?
Forum topic
Hi Everyone,
Has anyone had success in finding organizations or programs that will recycle the hard hats? We are looking into options for recycling our expired hard hats that can no longer be used. Ideally, we would want to use a company with facilities across the country but we are open to any suggestions or ideas you all may have.... Read more
Forum topic
Hi folks,
I'm looking into lower-carbon pipe options for HVAC and plumbing. The MEP 2040 has slides from a Buro Happold study in 2020 showing PEX to be much lower in embodied carbon than copper, which is unsurprising. CPVC is also a lower-carbon option.
But PVC has its issues and neither PVC nor PEX are recyclable (especially if... Read more
Forum topic
Dear SDL: Thanks to all who have already given their support to the AIA Resolution on Urgent and Sustained Climate Action. We're into the final push of getting out the vote to pass the resolution next Wednesday, June 5th afternoon in Las Vegas. This requires 2/3s of the voting delegates to pass. So we're asking anyone who 1) is attending as a... Read more
Forum topic
Hi there SD Leaders,
We're running an LCA on one of our projects that's about to start construction that has had serious embodied carbon goals and I got a result that really surprised me. I haven't been able to find any obvious/glaring issues with the work, but these results are strange enough that I'm not feeling confident. I'm hoping... Read more
Forum topic
Hello Gurus,
I have a client (bldg owner) who has asked me to recommend a list of firms who have the internalized resilient design in their practice.
They are *not* asking for resiliency consultants right now, but for firms that they might hire for "regular" capital projects, but since resiliency is high on their priorities, they... Read more
Forum topic
A brief non-technical rant about OneClick LCA - from someone who is not actually USING the tool, but lobbying for its access. Wondering if you all have better intel, or if it is just me.
We are working on a number of projects for which te teams are using OneClick LCA - for some cases it has a better international data set than others. ... Read more
Forum topic
All,
I've probably spoken to a few of you over the phone, but I wanted to make sure all of you know that we are hosting a 4 part webinar series on our Tally LCA software, kicking off tomorrow 10/10. We just released the new of Tally version and ended up doing far more development work than initially anticipated, in no small part due to... Read more
Forum topic
Hello Green Gurus,
Now is a pivotal moment. Net Zero Stretch Code legislation has been proposed in the Massachusetts House and Senate, and draft code language is currently being developed by the Board of Building Regulations and Standards (BBRS). The Net Zero Stretch Code is currently the greatest single opportunity to support reduced... Read more
Forum topic
Has anyone completed an LCA for an engineering structures lab, particularly one that has a strong wall and strong floor?