Forum topic
We've been doing some work gathering actual energy data on our recent projects. (In January we actually issued a report on 21 public buildings ).
One of the biggest issues is getting access to the actual data - many clients don't want to share.
Has anyone crafted proposal or contract language allowing/requiring design team... Read more
Forum topic
Just an FYI that BG's web team is planning on attending your meeting at 1:00 EDT. We will need information on how to join since the info in the invite didn't work last time.
See you all then.
Forum topic
Have any of you heard of anyone ever using phase change material (PCM) "movable partitions" as a resiliency strategy to mitigate indoor overheating during a heat wave in passive buildings? You'd keep them stored in a basement or cool room, and deploy them into habitable spaces during the heat wave to keep the space cooler than the exterior... Read more
Product Guide
Board insulation has good thermal performance ranging from about R-4 to R-8 and is used as an integral part of a building envelope’s continuous insulation system.
Because board insulation is used on the building exterior, it is not always subject to the same material health and emissions requirements as batt insulation used inside the... Read more
Quiz
Welcome to the quiz portion of Fundamentals of High-Performance Building Assemblies.
Learning Objectives
Upon completing this course, participants will be able to:
1. Recall how the acronym ENDURE speaks to the unifying aspect of high-performance buildings.
2. Describe how to apply the principles of high-... Read more
Forum topic
Hi all,
We know preparations for Greenbuild are well underway for many of you. We also know that there will be many things competing for your time while you're there. Here's one more to consider! We don't have all the details solidified yet, but wanted you to know sooner rather than later for planning purposes.
We hope you’ll... Read more
Forum topic
Hi all,
I'm curious if anyone has insight as to the "New Federal Building Performance Standards" that were announced in May of 2021 and then referenced again when E.O. 14057 came out. The memorandum for heads of agencies that was sent out with E.O. 14057 said that the CEQ would issue these standards, but I can't find a commitment to when... Read more
Forum topic
I wanted to let you all know about this Built Environment Plus Roundtable coming up on Thursday afternoon 3:00 est. We will be having a discussion around the IRA and how to implement the incentives on projects and help our clients understnad what it means for them. This is an informal setting where people can ask questions or share experiences... Read more
Forum topic
On behalf of the LFRT IRA working group, I am writing to see if anyone has applied for IRA funding (48E, 45L, 179D) for their project, and is willing to share their experiences and basic project info with us. We can keep the project name confidential if needed.
Thank you!
Forum topic
Dear all,
For a specific existing building application, we are looking for a half inch insulating glazing unit, preferably with low-e coating. Based on my research, 5/8" seems to be doable (1/8" glass + 3/8" air gap + 1/8" glass) but I'm yet to find a viable 1/2" solution. Have you come across any on your projects? Thanks for your... Read more
Forum topic
Do you have the authority to start using only EVs in your renderings? Let’s normalize and accelerate this change!
https://en.wikipedia.org/wiki/List_of_production_battery_electric_vehicles
Why are we showing gas cars in renderings of our green buildings?
Forum topic
Kristen Fritsch, in the thread about ipe wood, asked about resources comparing the carbon footprint of transporting building materials vs the transport mode. There are people who spend their lives on this topic that I won't presume to speak for, but I'll share a few observations:
Even though freight transport is something like 7% of... Read more
Forum topic
Friends, I reviewed the firm's 2019 AIA 2030 data with a Principal, having organized the data in such a way that we could manipulate it. I included the average EUI and weighted EUI, since the latter gives a truer picture of where we are as a studio. In the past, the assumption was we would raise all boats with efforts to improve our practice in... Read more
Portal
The current Stantec/BuildingGreen featured topic is Resilient Design. Read on to learn the essentials, and then dive deep to earn CEUS.
Also see the Material Health featured topic, and also a survey of topics trending in Stantec’s regions.... Read more
Forum topic
We are working on a tenant improvement and want to determine the embodied carbon on bookshelves, product display cases, and desks. Initially finding that Tally is not reading furniture, casework, or fixture families. Are there any tips and tricks you have found to be successful for modeling or defining FFE items in Revit and quantifying... Read more
Forum topic
Hello all,
Wondering if anyone has experience with lead limits in electrical cable and wiring?
LEED for Healthcare allows a limit of 300 ppm of lead in electrical wire and cabling - my search for compliant products has been all dead ends. (MRc PBT Source Reduction - lead, cadmium, and copper)
Acceptable regulations for... Read more