Hey SDL,

I'm curious if anybody out there has developed specification language requiring a certain level of airtightness (as assessed via one or a series of blower door tests) for a commercial project when it is not going for a Passive House certification and a blower door test is not required by code--basically, something in the... Read more

Forum topic

Hi all,

We have a newly constructed, core/shell project having some hot water issues in the core restrooms.

There is a 0.35 Toto lav installed throughout. The hot water heaters are adjacent on each floor, located in the janitor closets. We did the math, and there could be a gallon of water standing and cooling in the pipe between... Read more

Forum topic

Hi All,

Has anyone dug into ASHRAE 2016 as part of the new v4.1 requirements or as codes start to adopt it? I recently presented on this and thought I should check my math to make sure I'm understanding and communicating this correctly.

My understanding is that there is a new reference baseline, that is essentially the ASHRAE 2004... Read more

Product Guide

The overwhelming majority of wallcoverings are flexible vinyl, laden with all the life-cycle concerns that come with PVC. Products used to contain orthophthalate plasticizers—which make up a large percentage of these products. Phthalates are not bound in the material and can slough off in dust, exposing occupants during everyday work or play.... Read more

Forum topic

Hi folks,

I'm looking into lower-carbon pipe options for HVAC and plumbing. The MEP 2040 has slides from a Buro Happold study in 2020 showing PEX to be much lower in embodied carbon than copper, which is unsurprising. CPVC is also a lower-carbon option.

But PVC has its issues and neither PVC nor PEX are recyclable (especially if... Read more

Forum topic

Good morning, All,

Just a bit of news this morning.  My family and I are moving back out west!  I am continuing in my current role with EwingCole, but will be doing so from Portland, Oregon.  Although North Carolina has a been a wonderful place for us for the past 13 years, it is time to be close to family in the northwest and southwest... Read more

Quiz

Welcome to the quiz portion of Verifying Performance with Building Enclosure Commissioning.

Learning Objectives
Upon completing this course, participants will be able to:


 

1. Reason why the enclosure is fundamental to a sustainable building.
2. Explain why energy goals are less likely to be achieved without... Read more

Forum topic

Hi Everyone - I'm posting this on behalf of Jeff Frost whom many of you know from his days as an SD Leader with SmithGroup and SERA and in his new role as head of Brightworks Sustainability's materials group.  I am excited to be working with Jeff on this concept of multi-attribute product scoring.  Cheers, Lona

Dear SDL’ers,

We’ve... Read more

Peer Network Event

Forum topic

Hello Everyone,

On September 9th a regional cross-network group gathered for the first in-person Peer Networks event since the beginning of the pandemic. All Peer Networks were represented at this Boston Region Mini-Summit! With this first one in the books, BuildingGreen is hopeful for paving the way to future regional events across the... Read more

Forum topic

Hi there SD Leaders,

We're running an LCA on one of our projects that's about to start construction that has had serious embodied carbon goals and I got a result that really surprised me. I haven't been able to find any obvious/glaring issues with the work, but these results are strange enough that I'm not feeling confident. I'm hoping... Read more

Forum topic

Hi, folks! 

I was recently asked if BuildingGreen could connect prospective speakers to an event organizer in Chicago. Beyond the leaders in the BuildingGreen networks relayed, I wanted to share that the exercise led me to the Women and Climate speaker database: https://www.womenandclimate.co/speaker-database 

When filtering by... Read more

Forum topic

Here are the links I mentioned at today's meeting:

Timeline:
https://docs.google.com/presentation/d/1RlN4t23uvBtxEzp4QuyqL-w5bqmE4P90...

BG Contacts and Responsibilities:
https://docs.google.com/document/d/1MWYuAEitjk7Zpc8KUNf1LwG3-5wK6sIlgwro...

BITuser Contacts and Responsibilities:
https://docs.google.... Read more

Forum topic

Greetings to all of the AEC SD Leaders (a.k.a. the Green Gurus)!

Over the last two months, the 32-member Build-Back-Better (BBB) letter working group has developed a robust list of first 100-days, built-environment-focused executive actions for the Biden administration to consider. Kara Kempski, the AIA’s Director of Federal Relations,... Read more

Campus-wide Group

Forum topic

Are there any metrics for % increase for building PH vs conventional?  These questions are always really hard- especially when there are none to compare to in area.

Forum topic

On a large sports project, we worked with the structural engineer to spec low carbon / high SCM concrete mixes. Much of the floor area will be sealed and polished concrete, and a concrete sub is pushing back on the SCMs saying they should not be above 20% (with a preference for 0%) for the polish to finish properly, per the manufacturer. Anyone... Read more