BuildingGreen Report

Forum topic

We have an MEP engineer that is calculating peak loads at about 6 times passive house levels on a large commercial building that is at or near passive house levels of insulation and air infiltration. We suspect one reason is that he is figuring a 50% efficiency level for the ERV. We are showing him ERV systems with 80-90% efficiency, but they... Read more

Firm-wide Group

Forum topic

It is with the greatest pleasure that I announce to this esteemed group the recognition of our very own and much-loved leader Nadav Malin as an Honorary AIA member. AIA COTE had the honor to serve as Nadav's sponsor and we are pleased and delighted with this outcome (but not surprised of course.) For the record, "The AIA recognizes the notable... Read more

Forum topic

Here's the Core Purpose for this group that came out of the Inaugural Summit.

We're off and running!

Forum topic

Hello - 

I am looking for the recording and the PDF/ slides that were shared 3/6 for the project process share-out/ 5 min presentations. It was super inspiring and I would like to refresh my memory of some of what was shared. Thank you!

–
Alison Nash 
AIA, LEED AP ID+C, CPHC, WELL AP
Associate | Sustainability... Read more

Spotlight Report

Biophilic design features are not just aesthetically pleasing; researchers have found that patients heal faster, workers are more productive, and children learn better when more elements of nature are present.

And yet there are still very few projects developed today that inspire a connection to life and the natural world. Some people... Read more

Forum topic

Hello Green Gurus,

Now is a pivotal moment. Net Zero Stretch Code legislation has been proposed in the Massachusetts House and Senate, and draft code language is currently being developed by the Board of Building Regulations and Standards (BBRS). The Net Zero Stretch Code is currently the greatest single opportunity to support reduced... Read more

Forum topic

We are having trouble sourcing a LEED compliant wallcovering adhesive. We specified Roman Pro-880 which is low VOC but doesn't have sufficient back up for TVOCs. Have you had success with other products?

Forum topic

***Cross-posting this from SCL Group***

Last year I was approached by Green Advantage, remember them from like 2005? There has been a LEED innovation credit for as long as I can remember.

Has anyone seen employed Green Advantage recently? Is anyone asking for it?

Do you see value in GCs/CMs/trades having this training... Read more

Forum topic

On a large sports project, we worked with the structural engineer to spec low carbon / high SCM concrete mixes. Much of the floor area will be sealed and polished concrete, and a concrete sub is pushing back on the SCMs saying they should not be above 20% (with a preference for 0%) for the polish to finish properly, per the manufacturer. Anyone... Read more

Forum topic

Hello,

We’re looking for Design Energy Code Equivalents for Chinese commercial energy codes. Do any of you have  any good sources? I’ve only found data comparing ASHRAE 90.1 2013 to the Chinese Code at that time. We understand the Chinese code require a 65-75% energy savings over the baseline but don’t have good information for defining... Read more

Author

Campus-wide Group

Basic page

Thank you for subscribing!

You’re about to start getting free updates on key news and intelligence you need to succeed and do your best work in the green building industry. We’ll also share special opportunities to get our premium content.

Continue to BuildingGreen »

Continue to LEEDuser »

Product Guide

Choose a photovoltaic (PV) system to fit your energy needs, budget, and the space you have for installing the modules.

BuildingGreen-Approved PV

BuildingGreen approves PV modules that have high warranted minimum power ratings and high PTC (PVUsa test conditions).

Building-integrated PV (BIPV) products approved by... Read more

Quiz

Auto-quiz used for CEUs for attendees of the 2023 SDL Winter Summit.

Forum topic

Are there any metrics for % increase for building PH vs conventional?  These questions are always really hard- especially when there are none to compare to in area.