Forum topic
We should probably agree on the correct spelling for what we at BuildingGreen are calling "BITuser." I noticed that on the Salesforce portfolio screenshot provided by Dennis, it's spelled "BIT User."
BITuser has the advantage of more closely resembling LEEDuser, but it has the disadvantage of looking a little weird in all-caps, as in... Read more
Forum topic
We have all these resources out here in the ether but it’s so hard to pull them into one spot! I was asked, last minute to join a client call today to help convince both the client (affordable housing developer) and the mechanical engineers to "stick with" a commitment to 100% electric design that was publicly stated when the competition was... Read more
Forum topic
Hi everyone - in doing a carbon footprint for our firm, does anyone know if buildings that we design as Architects considered scope 3 emissions, or are they beyond the boundary of emissions? LMN's buildings, despite best efforts, are cumulatively multiple orders of magnitude above our scope 1 and 2 emissions. We have never included these... Read more
Quiz
Welcome to the quiz portion of BuildingGreen’s Top 10 Green Building Products for 2018.
Learning Objectives
Upon completing this course, participants will be able to:
1. Explain the transparency and optimization criteria in the LEED v4 (applicable to Building Product Disclosure and Optimization credits in LEED v4 BD+C and... Read more
Forum topic
I'm looking to compile an outdoor weather station for a local project, and we'd like to add local outdoor CO2 information to our data. I usually work with Onset HOBO products, but they don't offer an outdoor CO2 sensor. Their weather stations can take data from any CO2 sensor with an analog output - does anyone have any suggestions?
Quiz
Welcome to the quiz portion of Avoiding the Global Warming Impact of Insulation.
Learning Objectives
Upon completing this course, participants will be able to:
1. Define “embodied global warming potential” and “lifetime global warming potential” as they relate to insulation materials.
2. Describe why some... Read more
Forum topic
The results from the "CogFx" study are compelling, showing that people in environments with low VOCs and low ambient CO2 levels score higher on tests of cognitive function. Specifically, they show that providing 40cfm of outdoor air per (actual live) occupant results in significantly higher scores than even the "Enhanced Ventilation" scheme... Read more
Forum topic
I'm working with a project team that is looking into bird control options to prevent nesting/roosting/pooping on the scrim that is designed to scrim their building's facade. They are looking at electrified tape, repellents, laser systems, etc -- Options that don't dramatically impact the building design. The products they're looking at claim... Read more
Forum topic
Hello lovely Green Gurus. Hope you all are well. I am wondering if anyone has installed an indoor sports floor that performed well and is low-emitting. This is for a multi-purpose gymnasium at a community center. Any chance? Thanks All!
Forum topic
Hello all,
Any Fitwel experts out there? I have a 30,000 sf boutique hotel + spa client who would like to certify under the Fitwel rating system but Fitwel folks are telling me that no scorecard is currently available to hotel clients (can't use mulit-tenant or resi, that a hotel scorecard is under development). Has anyone used Fitwel... Read more
Forum topic
Folks, it is with a heavy heart that I write this: Lance Hosey passed away unexpectedly on Friday.
Many of you know him from the early days of the SDL group, or as an outsized presence at any of the many conferences where we overlap. He's been a list-maker, poll-taker and all around troublemaker in my life for over 20 years; I know I am... Read more
Forum topic
Hi All,
Has anyone successfully adopted a Revit to ClimateStudio workflow with their new export tool? Right now we are using cove.tool because it works reasonably well with iterative Revit modeling, but are itching to try a more accurate and nuanced alternative.
Thanks for any and all experiences!
Misha
Forum topic
Hello fellow sustainable design leaders! I am about to kick off an intensive effort here at EHDD to refine our internal standards for materials. We will be considering both GWP as well as the health of materials (avoiding harmful chemicals). In addition to setting the standards, I will be working to develop a process to vet materials before... Read more
Forum topic
We have a client who is asking us to design a roughly 10 ksf Wellness Center for PHIUS 2021 certification. The program includes several high density assembly type spaces - roughly 300 person peak occupant load for the building. The Criteria Calculator that the architect showed us puts the building peak cooling load at 4 BTUH/sf (3000 sf/ton... Read more
Forum topic
Hi all,
We have a project in New Orleans that needs to meet the GSA Inflation Reduction Act (IRA) requirements and submit EPDs. For our concrete, there is only one manufacturer that meets the requirements and is more than 50 miles away (according to EC3). Does anyone have tips on attempting to talk to local concrete manufacturers about... Read more