BuildingGreen Report

Product Guide

Food waste is a major source of greenhouse gas emissions from landfills due to methane released during anaerobic decomposition.

BuildingGreen-Approved Composters

BuildingGreen approves in-vessel commercial composters, which require the smallest footprint and are most likely to be suitable for a densely populated area.

Why... Read more

Forum topic

Hey SDL,

I'm curious if anybody out there has developed specification language requiring a certain level of airtightness (as assessed via one or a series of blower door tests) for a commercial project when it is not going for a Passive House certification and a blower door test is not required by code--basically, something in the... Read more

Forum topic

Hello Sustainable Design Leaders!

Here are the details for an upcoming SDL Peer Network web call, this webinar will be a call to share research and resources around mass timber. Hope to see you there!
REGISTER HERE!

Embodied Carbon and Mass Timber – a shared learning conversation
March 31st, 2020
3pm - 4pm ET (... Read more

Forum topic

If only a few of the Best Practices will have checklists, which will be included under the "Implementation Toolkit" tab, I'm thinking we can simplify them (compared with LEEDuser).

I've attached a screenshot of a LEEDuser checklist. But I don't think BITuser will need the four types of icons, and the legend will take up more space than... Read more

Team Group

Forum topic

We have an MEP engineer that is calculating peak loads at about 6 times passive house levels on a large commercial building that is at or near passive house levels of insulation and air infiltration. We suspect one reason is that he is figuring a 50% efficiency level for the ERV. We are showing him ERV systems with 80-90% efficiency, but they... Read more

Author

Forum topic

Hi Everyone.  Hope you and your families are all healthy and safe.

We are starting to figure out how we are going to implement the Contractors Commitment at my company, and we're using the opportunity to simultaneously set corporate wide and jobsite metrics and goals for sustainability tracking.

Each year we issue a sustainability... Read more

Campus-wide Group

Forum topic

Hi everyone! Our sister company, Flatiron, is a heavy civil/infrastructure contractor based out of Broomfield, CO. Their sustainability team is on the hunt for a Circular Economy Manager. Our companies recently announced exciting public ESG and climate commitments, including several related to waste reduction, life cycle assessments, and more... Read more

Author

Ben Hewitt works behind the scenes to build and maintain BuildingGreen.com and LEEDuser. He brings with him over two decades of experience in his field. As an efficient problem-solver, his goal is to make the websites more user-friendly for his coworkers and designers and project teams using BuildingGreen’s resources.

Ben has proficiency... Read more

Forum topic

Happy Thursday, all!

I will be presenting with my colleague, Emily Hoffman, and our counterpart from Seattle, Duane Jonlin, on how firms can contribute more to aggressive energy and carbon targets, from the perspective of three people that see thousands of projects each year.  We see the best and the worst, and we're convinced that our... Read more

Forum topic

If anyone else has gotten confused going between parts-per-million and percentages (parts per hundred!) for material reporting here's a little infographic that might help. Feel free to use or improve! 

Basic page

Peer Networks Application for Peer Network Membership Sages

The Sages network is specifically for industry veterans and long-time Peer Network members, including those who are still active with one of the other networks and those who have moved on from that role. This group can help set priorities, drive advocacy, and... Read more

Forum topic

Hello SDL!

Has anyone set "Ecosystem Benefits/Service" targets for an individual project or for all their projects? I was previously against the idea of even measuring ecosystem benefits but I've had my mind changed in recent months!

Currently we want to set a target for every project to: "Improve ecosystem benefits on every site... Read more

Forum topic

Here's the Core Purpose for this group that came out of the Inaugural Summit.

We're off and running!

Forum topic

Has anyone completed an LCA for an engineering structures lab, particularly one that has a strong wall and strong floor? 

Forum topic

On a large sports project, we worked with the structural engineer to spec low carbon / high SCM concrete mixes. Much of the floor area will be sealed and polished concrete, and a concrete sub is pushing back on the SCMs saying they should not be above 20% (with a preference for 0%) for the polish to finish properly, per the manufacturer. Anyone... Read more