Forum topic
Have any of you come across aqueous ozone product for hand sanitation? https://www.3oescientific.com/
This company is selling to hospitals/schools. May indeed be awesome, but so many "totally safe" products are proven not to be. Curious if this group has seen it or have looked at it's claims.
Forum topic
Call for Reviewers and Call for Proposals now out. If you're not planning on submitting a proposal to present, please consider volunteering as a reviewer, subject matter expert or member of the Program Working Group. The quality of the education program is directly proportional to the people who select it!
See many of you in Alabama... Read more
Forum topic
Hi All,
We are trying to make a case for hiring a full time sustainability specialist in our firm, and one of the arguments we want to use is that the ratio of sustainability specialists vs the ratio of full time employees in our company is quite low. That being said, I want to have an understanding of where other firms stand with this... Read more
Forum topic
Hello Sustainable Construction Leaders,
Save the date! The network's next quarterly call is scheduled for 1pm ET (10am PT), Tuesday November 16th. Topic TBD. Steering Group member Emi LaFountain from Turner will be leading the conversation.
Keep an eye on this thread for more details and Zoom information.
Jen
Forum topic
Hi folks,
I'm looking into lower-carbon pipe options for HVAC and plumbing. The MEP 2040 has slides from a Buro Happold study in 2020 showing PEX to be much lower in embodied carbon than copper, which is unsurprising. CPVC is also a lower-carbon option.
But PVC has its issues and neither PVC nor PEX are recyclable (especially if... Read more
Forum topic
Hi all - I’m wondering if any of you have heard of or use the National Green Building Standard, which appears to be primarily for residential and mixed use: https://www.homeinnovation.com/green.
The NGBS Green certification program is based on the ICC-700 National Green Building Standard and supposedly is the program of choice for many... Read more
Forum topic
Following up on one of our conversations on the vision vacuum and sustainability beyond certifications, I would like to help facilitate an offline conversation with anyone working within their firm to use the AIA COTE measures as a guiding framework in their firms/projects. Attached are my slides on my first pass at thinking about this at Page... Read more
Forum topic
Hi all,
We have a newly constructed, core/shell project having some hot water issues in the core restrooms.
There is a 0.35 Toto lav installed throughout. The hot water heaters are adjacent on each floor, located in the janitor closets. We did the math, and there could be a gallon of water standing and cooling in the pipe between... Read more
Forum topic
Hi SD Leaders,
As you may be aware, this past April a group of manufacturers calling themselves the Living Product 50 responded to the letters that many of us sent about five years ago advocating for transparency in their product ingredients. A copy of that letter can be reviewed about midway through the page at this link: https://... Read more
Product Guide
The overwhelming majority of wallcoverings are flexible vinyl, laden with all the life-cycle concerns that come with PVC. Products used to contain orthophthalate plasticizers—which make up a large percentage of these products. Phthalates are not bound in the material and can slough off in dust, exposing occupants during everyday work or play.... Read more
Forum topic
Have any of you relied on Green Badger for LEED documentation on projects?
I am familiar with the tool and know Tommy from my time in Atlanta, but have not used it on a construction project.
Have you found value? Thoughts?
Either way, they publish a pretty nifty "LEED v4 Construction Tool Kit" that may be useful for your... Read more
Forum topic
Hey SDL,
I'm curious if anybody out there has developed specification language requiring a certain level of airtightness (as assessed via one or a series of blower door tests) for a commercial project when it is not going for a Passive House certification and a blower door test is not required by code--basically, something in the... Read more
Forum topic
Hi all!
I've heard several people talk about developing tools for assessing/codifying a client's values for a project as part of an integrated design process (ie. a set of questions, survey, etc.). Would anyone be willing to share?
(Z, are you listening? I specifically recall you mentioning a tool like this...)
Thanks!... Read more
Forum topic
We are having trouble sourcing a LEED compliant wallcovering adhesive. We specified Roman Pro-880 which is low VOC but doesn't have sufficient back up for TVOCs. Have you had success with other products?
Forum topic
Gather with the Changemakers in Sustainable Construction