Championing the
Changemakers
BuildingGreen champions the changemakers in sustainable design and building, with trusted insight, unparalleled education, and communities that are transforming the industry.
Log in to your profile
Image: Piranka
Forum topic
What do you specify for the laboratory countertop? Are there any healthier options I should suggest to my team? Thank you!
Forum topic
Hello- If you use Procore....
Are your jobs using a template to conduct and create "reports" of their IAQ inspections? Did you set it up in forms or inspections? Would you mind sharing an example template with me? I know Green Badger has a great app to do this, which we use. We would use inspections in Procore for jobs that are not using... Read more
Product Guide
Depending on seating type, these products can contain PVC, toxic flame retardants, hazardous adhesives and finishes, and other unsustainable materials.
BuildingGreen-Approved Seating
BuildingGreen’s seating meets ONE of the following sets of criteria:
is certified to BIFMA’s level 3 standard and, where applicable, contains... Read moreForum topic
Hi all - I’m wondering if any of you have heard of or use the National Green Building Standard, which appears to be primarily for residential and mixed use: https://www.homeinnovation.com/green.
The NGBS Green certification program is based on the ICC-700 National Green Building Standard and supposedly is the program of choice for many... Read more
Forum topic
Does anyone have a spreadsheet or chart that compares the new Fitwel v2.1 with Fitwel v2.0 ?
I can't seem to find such a thing on the Fitwel website.
I am trying to determine which version-route to take on our "Workplace" project.
Or do you have experience in this that you can relay?
Thanks.
Forum topic
Hi folks,
I'm looking into lower-carbon pipe options for HVAC and plumbing. The MEP 2040 has slides from a Buro Happold study in 2020 showing PEX to be much lower in embodied carbon than copper, which is unsurprising. CPVC is also a lower-carbon option.
But PVC has its issues and neither PVC nor PEX are recyclable (especially if... Read more
Forum topic
Following up on one of our conversations on the vision vacuum and sustainability beyond certifications, I would like to help facilitate an offline conversation with anyone working within their firm to use the AIA COTE measures as a guiding framework in their firms/projects. Attached are my slides on my first pass at thinking about this at Page... Read more
Forum topic
A brief non-technical rant about OneClick LCA - from someone who is not actually USING the tool, but lobbying for its access. Wondering if you all have better intel, or if it is just me.
We are working on a number of projects for which te teams are using OneClick LCA - for some cases it has a better international data set than others. ... Read more
Quiz
Welcome to the quiz portion of LEED 2009: The Missing Manual.
Learning Objectives
Upon completing this course, participants will be able to:
1. Stay abreast of changes to LEED NC-2009.
2. Understand the more ambiguous aspects of LEED NC-2009.
3. Explain key interpretations of LEED NC-2009.
4.... Read more
Forum topic
We are having trouble sourcing a LEED compliant wallcovering adhesive. We specified Roman Pro-880 which is low VOC but doesn't have sufficient back up for TVOCs. Have you had success with other products?
Forum topic
We have an MEP engineer that is calculating peak loads at about 6 times passive house levels on a large commercial building that is at or near passive house levels of insulation and air infiltration. We suspect one reason is that he is figuring a 50% efficiency level for the ERV. We are showing him ERV systems with 80-90% efficiency, but they... Read more
Forum topic
The COTE Toolkit just launched on AIA.org's site, please go and check it out and share with your networks. The project spanned over the last year+ with over 40 authors, subject matter experts, and reviewers contributing to the process, (including many Green Gurus!)
With the goal of closing the information gap to designing high... Read more
Forum topic
Have any of you relied on Green Badger for LEED documentation on projects?
I am familiar with the tool and know Tommy from my time in Atlanta, but have not used it on a construction project.
Have you found value? Thoughts?
Either way, they publish a pretty nifty "LEED v4 Construction Tool Kit" that may be useful for your... Read more
Forum topic
Hello all,
This month's SCDL call was full of great discussion! We decided this month that we are feeling good about where we are for the Task Force Agreement on defining social sustainabiltiy in our work. The aim is to work with this agreement for a while and see if it holds up as a process framework. There was also interest to invite... Read more
Forum topic
Hi all,
We have a newly constructed, core/shell project having some hot water issues in the core restrooms.
There is a 0.35 Toto lav installed throughout. The hot water heaters are adjacent on each floor, located in the janitor closets. We did the math, and there could be a gallon of water standing and cooling in the pipe between... Read more