Forum topic

Can anyone point me to a (dream?) resource listing effective R-values of various wall assemblies?  We are trying to find a cost-effective R-40 wall assembly for a one and two story public middle school targeting net zero energy in Oregon.  Referencing Seonhee's "thermal bridging" thread in late April, I used Therm's native drawing feature, but... Read more

Forum topic

Hi Everyone- as a follow up to the 5 minute presentation I did during the recent Virtual Summit-Palooza, I am pleased to announce that the Sustainability Action Plan Guidance Document created by the AIA 2030 Working Group is finished and released.  Please share!

http://content.aia.org/sites/default/files/2021-03/... Read more

Campus-wide Group

Forum topic

Hello all, excuse the blast and the short timeline -- while not explicity sustainability-related, this is a great way to connect with the future of the profession, and can be a great opportunity for SDL firms on the west coast (a number of SDL firms already participate), specifically in Tacoma, Olympia, San Francisco, Sacramento, or San Diego.... Read more

Forum topic

I was wondering if any of you have experience with integrated PVs and/or solar glass. If so, can you could recommend manufactures for each? We are working on a multistory freestanding building in an urban site for a mid-Atlantic city. Because our site and roof area are limited we are looking to maximized the areas where we can generate power.... Read more

Forum topic

A brief non-technical rant about OneClick LCA - from someone who is not actually USING the tool, but lobbying for its access.  Wondering if you all have better intel, or if it is just me.

We are working on a number of projects for which te teams are using OneClick LCA - for some cases it has a better international data set than others. ... Read more

Product Guide

Alerting building occupants about indoor air pollutants is important in many situations.

BuildingGreen-Approved IAQ Equipment

Products approved by BuildingGreen range from single-use test kits to monitoring systems installed throughout a building. Some test for gases such as radon, VOCs, or carbon monoxide, and some for mold and... Read more

Forum topic

Hi all!

I've heard several people talk about developing tools for assessing/codifying a client's values for a project as part of an integrated design process (ie. a set of questions, survey, etc.). Would anyone be willing to share?

(Z, are you listening? I specifically recall you mentioning a tool like this...)

Thanks!... Read more

Forum topic

Love books? Want some inspiration? Join this Goodreads group with the following link... 

https://www.goodreads.com/group/invite/873351-green-gurus-goodreads-grou... (this link will be active for 30 days so let me know if you get here late and need it again)

I set this up as "private" so I will need to approve you. Anyone will be... Read more

Forum topic

Hi there colleagues!

Out of curiosity, do you plan on attending Greenbuild in person in San Diego in September? My staff asked me if we were going and my answer is partially contingent on the extent to which attending would mean getting to see some of our favorite people (read: all of you). Looking forward to taking the temperature of... Read more

Forum topic

We have an MEP engineer that is calculating peak loads at about 6 times passive house levels on a large commercial building that is at or near passive house levels of insulation and air infiltration. We suspect one reason is that he is figuring a 50% efficiency level for the ERV. We are showing him ERV systems with 80-90% efficiency, but they... Read more

Quiz

Welcome to the quiz portion of The Hidden Science of High-Performance Building Assemblies.

Learning Objectives
Upon completing this course, participants will be able to:


 

1. Define hygrothermal pressure and explain what it requires of water, air, and thermal barriers in high-performance assemblies.
2. Explain... Read more

Forum topic

Hi folks,

I'm looking into lower-carbon pipe options for HVAC and plumbing. The MEP 2040 has slides from a Buro Happold study in 2020 showing PEX to be much lower in embodied carbon than copper, which is unsurprising. CPVC is also a lower-carbon option.

But PVC has its issues and neither PVC nor PEX are recyclable (especially if... Read more

Forum topic

Hi All,

Has anyone dug into ASHRAE 2016 as part of the new v4.1 requirements or as codes start to adopt it? I recently presented on this and thought I should check my math to make sure I'm understanding and communicating this correctly.

My understanding is that there is a new reference baseline, that is essentially the ASHRAE 2004... Read more

Forum topic

Jenny/Dan:

What types of content do anticipate having in the Documentation Toolkit tab? Here's an example of what we have on LEEDuser:

https://leeduser.buildinggreen.com/credit/EBOM-2009/SSc5#tab-docs (login required)

The layout is a little complicated on LEEDuser, since we had to work with a lot of legacy content, but... Read more

Forum topic

Hi everyone,

Have your projects explored, pursued, or successfully achieved the domestic content bonus for PV systems within the Inflation Reduction Act (IRA) Investment Tax Credit? I have a project that is considering adding the IRA domestic content requirements and we are trying to understand the nuances and potential challenges (cost... Read more