BuildingGreen Report

Forum topic

Hi everyone,

Have your projects explored, pursued, or successfully achieved the domestic content bonus for PV systems within the Inflation Reduction Act (IRA) Investment Tax Credit? I have a project that is considering adding the IRA domestic content requirements and we are trying to understand the nuances and potential challenges (cost... Read more

Forum topic

Hi there SD Leaders,

We're running an LCA on one of our projects that's about to start construction that has had serious embodied carbon goals and I got a result that really surprised me. I haven't been able to find any obvious/glaring issues with the work, but these results are strange enough that I'm not feeling confident. I'm hoping... Read more

Author

Quiz

We think fresh water supplies are endless, but this idealistic vision is clouded by the smoke of countless forest fires in the U.S. West and elsewhere. Instead of endless bounty, climate change is bringing us catastrophic droughts and flooding that now dominate the headlines and threaten entire regions.

This report covers innovative... Read more

Campus-wide Group

Author

Boyd is part of the marketing team at BuildingGreen, where he supports analytics and social media engagement.

Boyd’s experience before joining BuildingGreen includes a decade in the paddlesports industry guiding whitewater trips as well as 5 years working in beer and wine manufacturing with a focus on customer interaction as well as... Read more

Reports, Courses, Study Guides, Live Webinars

THIS WEBINAR PURCHASE AND REGISTRATION IS CLOSED.

HPBA Control Layers – It’s in the details Tue, Sep 11, 2018 2:00 PM - 3:00 PM EDT (11:00 AM - 12:00 PM PT)

Why high-performance assemblies? And why now? Today we demand better thermal performance from our building assemblies than ever. But higher performance... Read more

Forum topic

A colleague just pointed out an article about M-Fire. Its a factory applied fire inhibitor for wood construction. It's GreenGuard Gold but I can't find any real information. Have any of you heard of this or have any idea what it actually is? https://www.bisnow.com/national/news/construction-development/this-new-tech-will-stop-fires-before-they... Read more

Forum topic

On LEEDuser we divide checklists into multiple project phases. Specifically:

Before the performance period Construction Construction documents Design development During the performance period Operations & maintenance Pre-design Schematic design

How many of these phases are relevant for BIT best practices?

Note that we also... Read more

Peer Network Event

Quiz

Welcome to the quiz portion of Cladding: More Than Just a Pretty Façade

Learning Objectives
Upon completing this course, participants will be able to:


 

1. Explain how different commercial wall assemblies handle moisture.
2. Know what questions to ask to determine a cladding system's environmental impact.... Read more

Forum topic

Hi everyone - in doing a carbon footprint for our firm, does anyone know if buildings that we design as Architects considered scope 3 emissions, or are they beyond the boundary of emissions? LMN's buildings, despite best efforts, are cumulatively multiple orders of magnitude above our scope 1 and 2 emissions. We have never included these... Read more

Forum topic

Under a high carbon scenario, most of North America will be 2 degrees C hotter by 2050. Meantime, we're designing buildings that will still be around in 2050, to codes that don't yet factor in chronic risks associated with climate change. I want to explain these risks to my colleagues; I'm hoping some of our green gurus can help answer the... Read more

Forum topic

Looking for an example or case study for a building utilizing a radiant heating/cooling in climate zone 4a. General use type is office with some public assembly spaces, total of 85,000 sf.

As usual, everyone, especially mechanical engineer, is terrified by the thought of "condensation." So far, I read a DGWW case study, "Energy... Read more

Forum topic

I'm looking to compile an outdoor weather station for a local project, and we'd like to add local outdoor CO2 information to our data. I usually work with Onset HOBO products, but they don't offer an outdoor CO2 sensor. Their weather stations can take data from any CO2 sensor with an analog output - does anyone have any suggestions?

Forum topic

Hello all, 

Any Fitwel experts out there? I have a 30,000 sf boutique hotel + spa client who would like to certify under the Fitwel rating system but Fitwel folks are telling me that no scorecard is currently available to hotel clients (can't use mulit-tenant or resi, that a hotel scorecard is under development). Has anyone used Fitwel... Read more

Forum topic

Does anyone know of a source for finding the operational solid waste generated by typical building/use types (weight/sf)? I couldn't find anything on LEED, True, or EPA. I found this table but isn't by sq ft for many of hte uses. Waste Generated by Industry and Building Type (wastecare.com)

Forum topic

Hello everyone,

Over the past couple of years the Climate Smart Wood Group has met monthly to discuss all things related to the use of timber in building design and construction.  From forestry practices, to supply chain and sourcing information, to design experiences and examples, the group has operated as an open forum for advancing... Read more

Forum topic

Hi all,

Looking from insights from anyone who's been through WELL certification before - we've got a lab/office project pursing WELL down in Florida that is struggling to meet the turbidity level requirements of the WELL W01 prerequisite, specifically with the hot water supply, and we're not sure how to best remediate the issue.  Should... Read more