BuildingGreen Report

Forum topic

Hey SDL,

I'm curious if anybody out there has developed specification language requiring a certain level of airtightness (as assessed via one or a series of blower door tests) for a commercial project when it is not going for a Passive House certification and a blower door test is not required by code--basically, something in the... Read more

Forum topic

If only a few of the Best Practices will have checklists, which will be included under the "Implementation Toolkit" tab, I'm thinking we can simplify them (compared with LEEDuser).

I've attached a screenshot of a LEEDuser checklist. But I don't think BITuser will need the four types of icons, and the legend will take up more space than... Read more

Forum topic

We have an MEP engineer that is calculating peak loads at about 6 times passive house levels on a large commercial building that is at or near passive house levels of insulation and air infiltration. We suspect one reason is that he is figuring a 50% efficiency level for the ERV. We are showing him ERV systems with 80-90% efficiency, but they... Read more

Forum topic

Hello friends,

We are embarking on calculations to quantify avoided embodied carbon from converting an old school building into a multifamily project and I wanted to vet our methodology with you.

Our idea is to first establish a benchmark for a new replacement multifamily building based on published studies. We have found a few... Read more

Forum topic

We had these conversations grouped by size of firm. 

Guiding Questions:

Knowledge Management By Firm Size

How to give people the info they need, when they need it?

Is the COTE Top Ten a good framework?

This seems extremely daunting in a large firm. How do we manage content that is produced and shared... Read more

Forum topic

If anyone else has gotten confused going between parts-per-million and percentages (parts per hundred!) for material reporting here's a little infographic that might help. Feel free to use or improve! 

Basic page

Last updated October 26th, 2022

What this policy covers

BuildingGreen, Inc. values your privacy. This notice describes what information we collect and how we use it.

To Users Resident in the European Economic Area:  This Privacy Policy will govern use of your personal information if you choose to use any... Read more

Forum topic

Hi All, this is primarily directed at our Sustainable MEP folks, but please anyone with insight feel free to weigh in.

I am increasingly seeing designs and specifications asking for Passive House levels of airtightness as verified by blower door testing, but with traditional ventilation system designs. 

To me, Passive House US has... Read more

Firm-wide Group

Forum topic

Hey Peer Network! Curious, if we can crowd-source a solution here for the pervious pavers at our Omaha office (climate zone 5A). Apparently over the years we've tried to add different kinds of fill here (gravel) but it keeps... disappearing. Any recommendations with either a replacement product or fill item? 

Forum topic

Hello Gurus,

I have a client (bldg owner) who has asked me to recommend a list of firms who have the internalized resilient design in their practice.

They are *not* asking for resiliency consultants right now, but for firms that they might hire for "regular" capital projects, but since resiliency is high on their priorities, they... Read more

Forum topic

Hi SD Leaders: I'm writing to get your help identifying any experts or projects where all-electric HVAC solutions are being implemented in a large new build healthcare/patient care setting. The client has raised concerns about the reliability of an electric re-heat system and its ability to promptly respond to temperature controls. They also... Read more

Forum topic

Hello,

We’re looking for Design Energy Code Equivalents for Chinese commercial energy codes. Do any of you have  any good sources? I’ve only found data comparing ASHRAE 90.1 2013 to the Chinese Code at that time. We understand the Chinese code require a 65-75% energy savings over the baseline but don’t have good information for defining... Read more

Quiz

Welcome to the quiz portion of Ten Strategies for Growth in a Recession.

Learning Objectives
Upon completing this course, participants will be able to:


 

1. Understand the importance of diversifying.
2. Restate the benefits to doing energy-modeling analysis very early in the design process.
3. Discuss how... Read more

Forum topic

I was recently tasked by my CEO to uncover some qualitative (interviews) and quantitative (surveys) data within our organization related to the value remote working has had on our organization. He's specifically interested in questions such as how this experience has enhanced our value as teams, unity or disunity as a firm? Where has it ... Read more

Forum topic

On a large sports project, we worked with the structural engineer to spec low carbon / high SCM concrete mixes. Much of the floor area will be sealed and polished concrete, and a concrete sub is pushing back on the SCMs saying they should not be above 20% (with a preference for 0%) for the polish to finish properly, per the manufacturer. Anyone... Read more

Product Guide

As with window and glazing products, the energy performance of skylights and roof windows varies greatly among different products and should be carefully considered.

BuildingGreen-Approved Skylights

BuildingGreen approves products that feature advanced thermally broken frames that dramatically reduce thermal bridging and improve... Read more