Forum topic
Looking for an example or case study for a building utilizing a radiant heating/cooling in climate zone 4a. General use type is office with some public assembly spaces, total of 85,000 sf.
As usual, everyone, especially mechanical engineer, is terrified by the thought of "condensation." So far, I read a DGWW case study, "Energy... Read more
Forum topic
Hello Sustainable Construction Leaders,
It's come to our attention that although we shared the slides from last fall's all-network Show & Tell in Atlanta, we neglected to include the presentations from the SCL Summit itself. Since we believe in "better late than never," here they are!
As a reminder: we have permission from... Read more
Forum topic
Hi friends,
We recently tracked our water consumption on site during the structural demolition of some existing reinforced concrete buildings. The new OSHA silica regulations required us to keep dust to virtually zero, so we had a bunch of mist cannons and water hoses pumping water around the clock. We consumed ~855,000 gallons in a... Read more
Basic page
The BuildingGreen/GreenStep exam prep materials are... Read more
Reports, Courses, Study Guides, Live Webinars
High-performance buildings integrate site-responsive orientation, climate-responsive form, hefty R-values, efficient mechanical systems, healthy... Read more
Forum topic
Hello fellow sustainable design leaders! I am about to kick off an intensive effort here at EHDD to refine our internal standards for materials. We will be considering both GWP as well as the health of materials (avoiding harmful chemicals). In addition to setting the standards, I will be working to develop a process to vet materials before... Read more
Forum topic
Hi All,
Has anyone successfully adopted a Revit to ClimateStudio workflow with their new export tool? Right now we are using cove.tool because it works reasonably well with iterative Revit modeling, but are itching to try a more accurate and nuanced alternative.
Thanks for any and all experiences!
Misha
Forum topic
We have a client who is asking us to design a roughly 10 ksf Wellness Center for PHIUS 2021 certification. The program includes several high density assembly type spaces - roughly 300 person peak occupant load for the building. The Criteria Calculator that the architect showed us puts the building peak cooling load at 4 BTUH/sf (3000 sf/ton... Read more
Forum topic
https://www.bostonglobe.com/metro/2018/06/04/new-china-policies-spark-di...
New China policies spark disarray in region’s recycling industry
Buried in the mountains of refuse at Casella’s recycling plant in Charlestown are tons of material that should have gone straight to the landfill — from tires and pots to lobster buoys and... Read more
Forum topic
My dear collegues,
As I'm sure is true for many of us, the events of the past weeks (months/years/decades...) have emphatically reinforced to me the need for a radical shift in how we meaningfully address JEDI in what we do. One (admittedly small) step I've been thinking about are the statements of reconciliation that have become more... Read more
Forum topic
Reminder: For anyone interested in continuing to participate in the Climate Smart Wood Working Group, please note that we have joined the other CSWG and will have our first meeting next Wednesday. Visit the Working Group page for the meeting invite and agenda.
Quiz
Welcome to the quiz portion of Rebuilding for Resilience in the Face of Natural Disasters!
IMPORTANT: This quiz covers three related articles within this topic.
Learning Objectives
Upon completing this course, participants will be able to:
Forum topic
All,
We are collecting examples of buildings that involved electrification initiatives (building does not need to be all electric as long as largely electric). Please share your projects with us through this short survey. It will take 8-10min to complete.
The study will culminate into a report and best practices to advocate for... Read more
Forum topic
We have an increasing number of projects, where the client is coming to us with "net zero" aspirations and plans, some of which don't fit the typical all-electric, grid-tied building that produces 100%+ of its annual energy use on-site. There include examples like:
1) A (targetd) living building that maximizes on-site production, with... Read more
Sales page
THIS WEBINAR REGISTRATION IS CLOSED.
Wondering how LEED v5 development is progressing? Here’s your chance to find out from two of the folks who’ve been closest to the process. Join us for this 45-minute event on July 26 at 11:30 Eastern (8:30 Pacific) .
LEEDuser hosted... Read more
Forum topic
Hi,
I selected a new background photo for the home page (the previous one was the same as on LEEDuser.com). I found the photo here:
https://www.pexels.com/photo/low-angle-shot-of-building-1029618/
I needed to find something low-contrast that wouldn't compete with the text. I initially tried some of the stock photos... Read more
Forum topic
Good morning all!
We're working on a higher ed project, and the university PM recently read an article about eco-friendly drywall and is interested in using it on the project. We're currently using the USG EcoSmart drywall on another project and mentioned it as an option, but the article she forwarded also mentioned ExtremeGreen's MgO... Read more
Forum topic
Hi All,
I just became aware of the attached detail (if I uploaded it correctly) for a project in Portland, OR going out for permit at the end of this week. Has anyone located the radiant tubing at the bottom of concrete like this before? It doesn't sit right with me, though I cannot pinpoint exactly why. Our consultants and the... Read more