Forum topic
Hi folks,
I'm looking into lower-carbon pipe options for HVAC and plumbing. The MEP 2040 has slides from a Buro Happold study in 2020 showing PEX to be much lower in embodied carbon than copper, which is unsurprising. CPVC is also a lower-carbon option.
But PVC has its issues and neither PVC nor PEX are recyclable (especially if... Read more
Forum topic
Hello- If you use Procore....
Are your jobs using a template to conduct and create "reports" of their IAQ inspections? Did you set it up in forms or inspections? Would you mind sharing an example template with me? I know Green Badger has a great app to do this, which we use. We would use inspections in Procore for jobs that are not using... Read more
Forum topic
If you use the mindfulMATERIALS library to easily access material transparency documentation (if not, check it out!), please take 5-10 mins of your time to fill out this quick survey and help guide the future of the library.
The mindfulMATRIALS Collaborative is an industry-led initiative, visit www.mindfulmaterials.com to learn more. ... Read more
Quiz
Welcome to the quiz portion of Take Control of Your Materials: Four Empowering Lessons from Teams That Beat the Red List.
Learning Objectives
Upon completing this course, participants will be able to:
1. Customize a framework to prioritize goals and simplify complex material decisions.
2. Use a red-list... Read more
Forum topic
Hello Green Gurus,
I wanted to take a moment and introduce myself as I am new to the group. My name is Tim Pranaitis and I am the co-chair of the newly-reformed sustainability committee at Steffian Bradley Architects in Boston, MA. As a newer member of my firm, I have been tasked to re-start and grow our sustainability committee which... Read more
Forum topic
Hi all,
We have a newly constructed, core/shell project having some hot water issues in the core restrooms.
There is a 0.35 Toto lav installed throughout. The hot water heaters are adjacent on each floor, located in the janitor closets. We did the math, and there could be a gallon of water standing and cooling in the pipe between... Read more
Forum topic
Hi there colleagues!
Out of curiosity, do you plan on attending Greenbuild in person in San Diego in September? My staff asked me if we were going and my answer is partially contingent on the extent to which attending would mean getting to see some of our favorite people (read: all of you). Looking forward to taking the temperature of... Read more
Forum topic
I was wondering if any of you have experience with integrated PVs and/or solar glass. If so, can you could recommend manufactures for each? We are working on a multistory freestanding building in an urban site for a mid-Atlantic city. Because our site and roof area are limited we are looking to maximized the areas where we can generate power.... Read more
Basic page
The High Performance Buildings Database (HPB) provides case studies of projects ranging from homes and commercial interiors to large buildings and even whole campuses and neighborhoods. These may be certified green projects, or simply projects that have one or more notable environmental features. We review each published case study to focus on... Read more
Forum topic
Hi, folks!
I was recently asked if BuildingGreen could connect prospective speakers to an event organizer in Chicago. Beyond the leaders in the BuildingGreen networks relayed, I wanted to share that the exercise led me to the Women and Climate speaker database: https://www.womenandclimate.co/speaker-database
When filtering by... Read more
Forum topic
If only a few of the Best Practices will have checklists, which will be included under the "Implementation Toolkit" tab, I'm thinking we can simplify them (compared with LEEDuser).
I've attached a screenshot of a LEEDuser checklist. But I don't think BITuser will need the four types of icons, and the legend will take up more space than... Read more
Forum topic
We have an MEP engineer that is calculating peak loads at about 6 times passive house levels on a large commercial building that is at or near passive house levels of insulation and air infiltration. We suspect one reason is that he is figuring a 50% efficiency level for the ERV. We are showing him ERV systems with 80-90% efficiency, but they... Read more
Forum topic
Hey all - sorry I won't be able to join our call today. I had a client request an emergency meeting today (boo) because corporate mandated that they eliminate fossil fuel use from all their buildings (yay!) by 2025 and they've got a project underway that needs to pivot quickly.
Had I been able to join, I wanted to share this in case... Read more
Forum topic
Hello,
We’re looking for Design Energy Code Equivalents for Chinese commercial energy codes. Do any of you have any good sources? I’ve only found data comparing ASHRAE 90.1 2013 to the Chinese Code at that time. We understand the Chinese code require a 65-75% energy savings over the baseline but don’t have good information for defining... Read more
Forum topic
Hi everyone,
Have your projects explored, pursued, or successfully achieved the domestic content bonus for PV systems within the Inflation Reduction Act (IRA) Investment Tax Credit? I have a project that is considering adding the IRA domestic content requirements and we are trying to understand the nuances and potential challenges (cost... Read more