Forum topic
Hey SDL,
I'm curious if anybody out there has developed specification language requiring a certain level of airtightness (as assessed via one or a series of blower door tests) for a commercial project when it is not going for a Passive House certification and a blower door test is not required by code--basically, something in the... Read more
Basic page
BuildingGreen Approved, like its predecessor, GreenSpec, is an independent product evaluation service for BuildingGreen members. We offer an unbiased look at products: BuildingGreen does not accept any manufacturer fees for our evaluations. Here’s a quick tour of the platform and how to use it.
Who can access BuildingGreen Approved... Read moreForum topic
Hi all,
We have a newly constructed, core/shell project having some hot water issues in the core restrooms.
There is a 0.35 Toto lav installed throughout. The hot water heaters are adjacent on each floor, located in the janitor closets. We did the math, and there could be a gallon of water standing and cooling in the pipe between... Read more
Forum topic
Gather with the Changemakers in Sustainable Construction
You are invited to join BuildingGreen and your peers for the Summit that has always delivered on driving our movement forward. Over three days of collaboration, workshops, learning, sharing, networking, and socializing, we’ll set the agenda for changes to LEED v5, strategize on... Read more
Forum topic
Hello -
I am looking for the recording and the PDF/ slides that were shared 3/6 for the project process share-out/ 5 min presentations. It was super inspiring and I would like to refresh my memory of some of what was shared. Thank you!
–
Alison Nash
AIA, LEED AP ID+C, CPHC, WELL AP
Associate | Sustainability... Read more
Forum topic
Hi All,
Has anyone dug into ASHRAE 2016 as part of the new v4.1 requirements or as codes start to adopt it? I recently presented on this and thought I should check my math to make sure I'm understanding and communicating this correctly.
My understanding is that there is a new reference baseline, that is essentially the ASHRAE 2004... Read more
Forum topic
If only a few of the Best Practices will have checklists, which will be included under the "Implementation Toolkit" tab, I'm thinking we can simplify them (compared with LEEDuser).
I've attached a screenshot of a LEEDuser checklist. But I don't think BITuser will need the four types of icons, and the legend will take up more space than... Read more
Forum topic
Dear SDL: Thanks to all who have already given their support to the AIA Resolution on Urgent and Sustained Climate Action. We're into the final push of getting out the vote to pass the resolution next Wednesday, June 5th afternoon in Las Vegas. This requires 2/3s of the voting delegates to pass. So we're asking anyone who 1) is attending as a... Read more
Forum topic
Hello Everyone,
On September 9th a regional cross-network group gathered for the first in-person Peer Networks event since the beginning of the pandemic. All Peer Networks were represented at this Boston Region Mini-Summit! With this first one in the books, BuildingGreen is hopeful for paving the way to future regional events across the... Read more
Forum topic
Hi Everyone - I hope this isn't a repeat topic. We are starting to get familiar with TallyCAT at SAR+ and have a few people testing our projects in it. Is anyone willing to help us troubleshoot or share lessons learned? We're running into a few errors and wonder if our Revit models and workflow are the issue, or if we need to be doing something... Read more
Spotlight Report
Biophilic design features are not just aesthetically pleasing; researchers have found that patients heal faster, workers are more productive, and children learn better when more elements of nature are present.
And yet there are still very few projects developed today that inspire a connection to life and the natural world. Some people... Read more
Forum topic
Hello Gurus,
I have a client (bldg owner) who has asked me to recommend a list of firms who have the internalized resilient design in their practice.
They are *not* asking for resiliency consultants right now, but for firms that they might hire for "regular" capital projects, but since resiliency is high on their priorities, they... Read more
Forum topic
Hi Carbon Working Group,
It’s been a while since our last online meeting on 3/31 –- admittedly, a bit too long -- so I wanted to share some updates. You might have seen Candice Pearson’s 5/13 post about the structure of the Contractor’s Commitment and how it’s evolving into a set of guidelines available not only to our SCL Group but to... Read more
Product Guide
As with window and glazing products, the energy performance of skylights and roof windows varies greatly among different products and should be carefully considered.
BuildingGreen-Approved Skylights
BuildingGreen approves products that feature advanced thermally broken frames that dramatically reduce thermal bridging and improve... Read more
Quiz
Welcome to the quiz portion of Ten Strategies for Growth in a Recession.
Learning Objectives
Upon completing this course, participants will be able to:
1. Understand the importance of diversifying.
2. Restate the benefits to doing energy-modeling analysis very early in the design process.
3. Discuss how... Read more
Forum topic
On a large sports project, we worked with the structural engineer to spec low carbon / high SCM concrete mixes. Much of the floor area will be sealed and polished concrete, and a concrete sub is pushing back on the SCMs saying they should not be above 20% (with a preference for 0%) for the polish to finish properly, per the manufacturer. Anyone... Read more