Product Guide
Pint-flush and non-water urinals can save tens of thousands of gallons of potable water per year. A single non-water-using urinal can save more than 10,000 gallons of water per year compared with the U.S. EPA standard of 1.0 gallon per flush (gpf).
When older 3.0 gpf urinals are replaced, the savings can be as great as 50,000 gallons... Read more
Forum topic
Who else is playing in this year’s #SustainabilityScavengerHunt by BE+!?
Meredith Elbaum and team at Built Environment Plus are launching the second annual hunt this Friday. Teams of up to four people compete over a couple of weeks to complete missions and bring awareness to environmental topics.
It was a lot of fun last year - we... Read more
Forum topic
Lauren Shumaker (Turner Construction) and I are starting a group to focus on improving the submittal process, currently focused specifically on healthy & sustainable materials and the use of the mindful Materials library. The purpose of this working group would be to align project management and LEED project software (ex: Procore, CMiC,... Read more
Forum topic
Team,
You probably know on July 9th, WHO issued a document and agreed aerosol route of COVID-19 transmission is possible, but fell short of saying we need to make provisions in our buildings for it per the "Do no harm" principle. Mary Ann Lazarus, Pauline Souza, Kay Sargent, Joyce Lee, and I (SDL members from architecture and... Read more
Author
Forum topic
Hi all,
Here's a good follow up to Maria's steel question on Monday. We have a Midwest project that unfortunately (from a carbon perspective) is required to use a traditional, thick precast facade. We’re working with the contractor and potential future (not yet bid out) fabricators to determine an appropriate % of pozzolanic material... Read more
Reports, Courses, Study Guides, Live Webinars
THIS WEBINAR PURCHASE AND REGISTRATION IS CLOSED.
Live webinar approved for 1 AIA LU and 1 GBCI CE hour. Each person intending to earn CEU credits must purchase their own seat.
Why high-performance assemblies? And why now? Today we demand better thermal performance from our building assemblies than... Read more
Forum topic
I'm looking to compare using an electric tower crane vs a diesel generated tower crane. I've got the average gallons/hour for the size of crane I'm looking at, but when I reached out to the crane manufacturers, they can only tell me what size electric supply I need to provide, not the kWh usage for the cranes. I know that it varies depending... Read more
Forum topic
Is anyone else working on a project doing Living Building Challenge v4.0 Energy Petal? We're working through the Imperative 08 Net Positive Carbon Resiliency Strategy requirements that ask for the project to be habitable for a week in the event of an emergency. We're curious how others are defining "habitable" and what systems assumptions... Read more
Forum topic
I'm passing on an alarming (and truly Orwellian!) message from the AIA that some may have received:
The AIA is aware (and has been actively addressing) that there is a draft executive order circulating for consideration by White House officials that would officially designate “classical” architecture as the preferred style for the... Read more
Quiz
Welcome to the quiz portion of The Problem with Net-Zero Buildings (and the Case for Net-Zero Neighborhoods).
Learning Objectives
Upon completing this course, participants will be able to:
1. Describe several unintended consequences of focusing on net-zero-energy buildings.
2. List at least three advantages... Read more
Forum topic
This month on our Sustainable MEP Leaders call we were asked what resources would be suggested for advancing integrative design.
Two books immediately came to mind for me:
How Building Learn, by Stewart Brand
https://en.wikipedia.org/wiki/How_Buildings_Learn
It was many years ago but reading Stewart Brand’s How... Read more
Forum topic
This are opportunities for us to get involved as design and construction allies with the new administration and the US Department of Energy on more efficient building.
The first link below is for low-carbon projects that will provide the case studies and solutions that the industry can follow. The second is identifying barriers and... Read more
Forum topic
Happy Friday, SDL!
We're running a Tally WBLCA for an environmental education center, which has a very small floor area but a fairly robust concrete/steel structure. Still, I was surprised to find an intensity of over 1,000 kgCO2/m2 for the building.
This is way higher than the general benchmarks I've found in the CLF's database,... Read more
Forum topic
Hello fellow Green Gurus!
I am very thrilled to share this news. "Global architecture, design and planning firm HLW is pleased to announce BEYOND, a cutting-edge sustainability consultancy working across the built environment to drive higher standards for sustainability, resilience, and building performance."
Please click here to... Read more
Forum topic
MSA has issued a safety advisory because they have received field reports that their green colored MSA V-Gard Protective Caps are cracking. Please share this with your safety staff if they do not already know. Let's keep everyone safe!
Forum topic
Show & Tell Breakout. Presentations:
Lessons learned from our Hopeworks Affordable Housing Project seeking LBC Petal Certification Optimize Solar Plugload and Power over Ethernet.