BuildingGreen Report

Product Guide

Hardware has to be durable and resist weathering to ensure that features such as doors function properly.

BuildingGreen-Approved Hardware

BuildingGreen approves hardware that uses post-consumer recycled metal content beyond what is standard in the industry. Products from manufacturers that have engaged in information transparency... Read more

Quiz

Welcome to the quiz portion of How to Build Green At No Added Cost

Learning Objectives
Upon completing this course, participants will be able to:


 

1. Know how to make a value proposition for green buildings.
2. Explain how shrinking a green building and investing in its envelope can reduce first costs of its... Read more

Forum topic

Hey SDL,

I'm curious if anybody out there has developed specification language requiring a certain level of airtightness (as assessed via one or a series of blower door tests) for a commercial project when it is not going for a Passive House certification and a blower door test is not required by code--basically, something in the... Read more

Campus-wide Group

Peer Network Event

Forum topic

Hi all - I’m wondering if any of you have heard of or use the National Green Building Standard, which appears to be primarily for residential and mixed use: https://www.homeinnovation.com/green.

The NGBS Green certification program is based on the ICC-700 National Green Building Standard and supposedly is the program of choice for many... Read more

Forum topic

Hello - 

I am looking for the recording and the PDF/ slides that were shared 3/6 for the project process share-out/ 5 min presentations. It was super inspiring and I would like to refresh my memory of some of what was shared. Thank you!


Alison Nash 
AIA, LEED AP ID+C, CPHC, WELL AP
Associate | Sustainability... Read more

Forum topic

Hi all,

We have a newly constructed, core/shell project having some hot water issues in the core restrooms.

There is a 0.35 Toto lav installed throughout. The hot water heaters are adjacent on each floor, located in the janitor closets. We did the math, and there could be a gallon of water standing and cooling in the pipe between... Read more

Forum topic

We have an MEP engineer that is calculating peak loads at about 6 times passive house levels on a large commercial building that is at or near passive house levels of insulation and air infiltration. We suspect one reason is that he is figuring a 50% efficiency level for the ERV. We are showing him ERV systems with 80-90% efficiency, but they... Read more

Forum topic

Hello,

We’re looking for Design Energy Code Equivalents for Chinese commercial energy codes. Do any of you have  any good sources? I’ve only found data comparing ASHRAE 90.1 2013 to the Chinese Code at that time. We understand the Chinese code require a 65-75% energy savings over the baseline but don’t have good information for defining... Read more

Forum topic

I was recently tasked by my CEO to uncover some qualitative (interviews) and quantitative (surveys) data within our organization related to the value remote working has had on our organization. He's specifically interested in questions such as how this experience has enhanced our value as teams, unity or disunity as a firm? Where has it ... Read more

Forum topic

Here's the Core Purpose for this group that came out of the Inaugural Summit.

We're off and running!

Forum topic

Hello Everyone,

On September 9th a regional cross-network group gathered for the first in-person Peer Networks event since the beginning of the pandemic. All Peer Networks were represented at this Boston Region Mini-Summit! With this first one in the books, BuildingGreen is hopeful for paving the way to future regional events across the... Read more

Reports, Courses, Study Guides, Live Webinars

Design assemblies that live up to their potential Course developer Peter Yost explains how high-performance assemblies are fundamentally different from traditional building assemblies.

High-performance buildings integrate site-responsive orientation, climate-responsive form, hefty R-values, efficient mechanical systems, healthy... Read more

Forum topic

Hello Green Gurus,

Now is a pivotal moment. Net Zero Stretch Code legislation has been proposed in the Massachusetts House and Senate, and draft code language is currently being developed by the Board of Building Regulations and Standards (BBRS). The Net Zero Stretch Code is currently the greatest single opportunity to support reduced... Read more

Forum topic

Good Morning,  I have so enjoyed reading everyone’s personal introductions.  I am happy to be a part of this group and look forward to working together to create transformation of an industry that is sometimes slow to move.  My name is Patty Lloyd and I am the Sustainability Manager at Leopardo Companies, a Chicagoland area General Contractor... Read more

Campus-wide Group

Sales page

With this special offer, you’ll get the Spec This Not That Report at the reduced price of $89, a $40 savings. Avoiding Toxic Chemicals in Commercial Building Projects


Can furniture be hazardous? You bet it can…

From flame retardants in foam cushions to unnecessary stain and dirt repellents on upholstery materials, everyday... Read more

Forum topic

On a large sports project, we worked with the structural engineer to spec low carbon / high SCM concrete mixes. Much of the floor area will be sealed and polished concrete, and a concrete sub is pushing back on the SCMs saying they should not be above 20% (with a preference for 0%) for the polish to finish properly, per the manufacturer. Anyone... Read more