Our all-volunteer Advisory Board helps BuildingGreen identify the most critical topics for our coverage, and directs our research as we investigate these topics and bring them to our readers. Their distinguished and varied service in the field of environmentally responsible building is an inspiration.
Steve Baczek, R.A., Reading, MA Bob... Read moreSpotlight Report
Older buildings—especially those from the 1950s, ’60s, and ’70s—need our help. Many leave something to be desired in terms of aesthetics and comfort. But the truth is that they are part of the urban and suburban fabric now, and they aren’t going anywhere. As tempting as it might seem to tear them all down and replace them with high-performance... Read more
Forum topic
Hi all,
We have a newly constructed, core/shell project having some hot water issues in the core restrooms.
There is a 0.35 Toto lav installed throughout. The hot water heaters are adjacent on each floor, located in the janitor closets. We did the math, and there could be a gallon of water standing and cooling in the pipe between... Read more
Forum topic
Dear SDL: Thanks to all who have already given their support to the AIA Resolution on Urgent and Sustained Climate Action. We're into the final push of getting out the vote to pass the resolution next Wednesday, June 5th afternoon in Las Vegas. This requires 2/3s of the voting delegates to pass. So we're asking anyone who 1) is attending as a... Read more
Forum topic
Hi All,
Has anyone dug into ASHRAE 2016 as part of the new v4.1 requirements or as codes start to adopt it? I recently presented on this and thought I should check my math to make sure I'm understanding and communicating this correctly.
My understanding is that there is a new reference baseline, that is essentially the ASHRAE 2004... Read more
Forum topic
Hi SDLers! I hope early fall is finding you well.
There is a current opportunity to make a difference in the campaign to reduce use of toxic flame retardants.
Arlene Blum and the Green Science Policy Institute, whom many of you know, are currently organizing a campaign of support for the CA State Fire Marshal's proposal to allow... Read more
Forum topic
Dear SD Leaders: The comment period closes January 31st on NCA Volume II Climate Change Impacts, Risks, and Adaptation in the United States.
It's important to have the design communities perspective on these critical issues. I hope you can take a look and submit your comments before the deadline.
Details here: https://www.... Read more
Forum topic
We have an MEP engineer that is calculating peak loads at about 6 times passive house levels on a large commercial building that is at or near passive house levels of insulation and air infiltration. We suspect one reason is that he is figuring a 50% efficiency level for the ERV. We are showing him ERV systems with 80-90% efficiency, but they... Read more
Quiz
Welcome to the quiz portion of Making Windows Work Better.
Learning Objectives
Upon completing this course, participants will be able to:
1. Understand when window attachments may be used in lieu of window replacements.
2. Summarize why optimal management of heat loss and gain may require both interior and... Read more
Forum topic
Hi everyone,
Have your projects explored, pursued, or successfully achieved the domestic content bonus for PV systems within the Inflation Reduction Act (IRA) Investment Tax Credit? I have a project that is considering adding the IRA domestic content requirements and we are trying to understand the nuances and potential challenges (cost... Read more
Forum topic
Good morning, All,
Just a bit of news this morning. My family and I are moving back out west! I am continuing in my current role with EwingCole, but will be doing so from Portland, Oregon. Although North Carolina has a been a wonderful place for us for the past 13 years, it is time to be close to family in the northwest and southwest... Read more
Forum topic
Hi Everyone - I hope this isn't a repeat topic. We are starting to get familiar with TallyCAT at SAR+ and have a few people testing our projects in it. Is anyone willing to help us troubleshoot or share lessons learned? We're running into a few errors and wonder if our Revit models and workflow are the issue, or if we need to be doing something... Read more
Forum topic
Hello SDL!
Has anyone set "Ecosystem Benefits/Service" targets for an individual project or for all their projects? I was previously against the idea of even measuring ecosystem benefits but I've had my mind changed in recent months!
Currently we want to set a target for every project to: "Improve ecosystem benefits on every site... Read more
Forum topic
Hello Everyone,
On September 9th a regional cross-network group gathered for the first in-person Peer Networks event since the beginning of the pandemic. All Peer Networks were represented at this Boston Region Mini-Summit! With this first one in the books, BuildingGreen is hopeful for paving the way to future regional events across the... Read more
Product Guide
Exterior doors often have poor insulation and seals that allow air through.
BuildingGreen-Approved Exterior Doors
BuildingGreen has different criteria for commercial and residential exterior doors.
Commercial swing (hinged) doors must be NFRC-rated, certified, and labeled for U-factor. They have a maximum air leakage of 0.... Read more