Forum topic
Dear all,
For a specific existing building application, we are looking for a half inch insulating glazing unit, preferably with low-e coating. Based on my research, 5/8" seems to be doable (1/8" glass + 3/8" air gap + 1/8" glass) but I'm yet to find a viable 1/2" solution. Have you come across any on your projects? Thanks for your... Read more
Forum topic
Dear Colleagues:
This is a request from AIA COTE Advocacy to sign another petition on behalf of your firm. I know it's incomprehensible that we have to do this, but we at AIA COTE Advocacy think the US Federal Emergency Management Agency's removal of the term "climate change" from all their strategic planning documents is evidence of an... Read more
Forum topic
We considering PV glazing for a project in SW Louisiana. Anyone have any successful PV glazing projects? Is this ready for primetime?
Basic page
A building project brings brothers back together, but a fast-moving storm challenges the project and the family.
Of storms & chins »
Whistleblowers alert state health agencies to possible foot fungus scourge... Read more
Forum topic
Hi All,
As I mentioned at the summit, I'd like to start a discussion thread on knowledge management, company Intranets, and limiting Information overload as it pertains to sustainability. Those who are interested can share thoughts and experiences via this thread and maybe we'll set up an occasional phone call.
Here are the... Read more
Reports, Courses, Study Guides, Live Webinars
Practitioners interested in reducing the embodied carbon of buildings are likely now used to considering the impact of different materials, like mass timber or low-carbon concrete. Low-carbon construction, however, may be less familiar.
Contractors are just... Read more
Forum topic
Our firm was asked by a government client in Canada to update their specifications for concrete to capture low embodied carbon as a performance metric. From the SDL group's knowledge of concrete procurement:
What are the chances of systematically obtaining cement specified with 10% lower carbon intensity? What's viable in the current... Read moreForum topic
Happy Friday, SDL!
We're running a Tally WBLCA for an environmental education center, which has a very small floor area but a fairly robust concrete/steel structure. Still, I was surprised to find an intensity of over 1,000 kgCO2/m2 for the building.
This is way higher than the general benchmarks I've found in the CLF's database,... Read more
Forum topic
Hi Everyone, just as governors are regionally deciding how to reopen their economies, it's probably time we started thinking about what getting back to work looks like for us. And, just as governors are leaning on each other for ideas and coordination, we can benefit from discussing strategies as a group. To that end, I wanted to get your... Read more
Forum topic
Hi All - I have a 3 bdroom close walking distance to Greenbuild venue - but I don't need it.
Last call before I cancel it - if anyone wants it - I can transfer!
Just shoot me an email directly to bb@sustainable-performance.org
Thanks and see you there!
Quiz
Sustainability leadership has requested that you take this quiz to help assess sustainability literacy across the firm. Your own results will be presented to you at the end of the quiz but will not be shared with anyone else. Only aggregated, anonymized results will be available to others.
Please don’t do research to inform your answers... Read more
Quiz
Welcome to the quiz portion of Designing for the Next Century's Weather
Learning Objectives
Upon completing this course, participants will be able to:
1. Understand how to adjust building designs to rising temperatures and humidity.
2. Recognize how climate-responsive buildings may not respond as expected in... Read more
Forum topic
Does adding solar panels reduce a building's EUI?
Existing operational use of a building is 80 kBtu/sf/year. When we add solar, it will change the source of energy but does not change the usage.
My understanding is that the EUI does not change, but it would be good to hear from others.
It's energy consumption at the point... Read more
Forum topic
Question for you all: there is this wonderful graph showing how we can shift mechanical and electrical dollars into envelope investments to make deep energy savings cost-neutral. Have you experienced this on a project?
1-minute or less survey! (two questions, more detail if you want)
https://docs.google.com/forms/d/e/... Read more
Forum topic
Hi folks,
We often hear from you with a suggestion of someone who would be great for the network, and a question about how to refer them. We've now made that easy, with three steps laid out in an Outreach Toolkit that's posted in the left margin of the Member Directory.
So, if you're thinking of someone to invite or come across... Read more
Forum topic
Does anyone here have a draft spec for low embodied carbon concrete they could share? I see the GSA has a standards sheet with MGWP limits, but we are hoping to actually specify the mix for upcoming projects.