BuildingGreen Report

Forum topic

We have an MEP engineer that is calculating peak loads at about 6 times passive house levels on a large commercial building that is at or near passive house levels of insulation and air infiltration. We suspect one reason is that he is figuring a 50% efficiency level for the ERV. We are showing him ERV systems with 80-90% efficiency, but they... Read more

Product Guide

Prefabricated, or modular, buildings can provide environmental advantages over conventionally constructed buildings. They are built in factories where manufacturing and cost can be tightly controlled, so materials are kept out of the elements, there is less waste, and thermal properties and air sealing can be enhanced. There are also fewer... Read more

Forum topic

I know that there is a risk of starting a whole flurry of congrats through the forum, but this is a biggie, and deserves some recognition:

Congratulations Andrea and Melanie!! Huzzah!!

And a reminder--If you want to reach out to them privately, rather than through the forum, with your message, you can see anyone's email address by... Read more

Forum topic

Hi all,

We have a newly constructed, core/shell project having some hot water issues in the core restrooms.

There is a 0.35 Toto lav installed throughout. The hot water heaters are adjacent on each floor, located in the janitor closets. We did the math, and there could be a gallon of water standing and cooling in the pipe between... Read more

Forum topic

Hey SDL,

I'm curious if anybody out there has developed specification language requiring a certain level of airtightness (as assessed via one or a series of blower door tests) for a commercial project when it is not going for a Passive House certification and a blower door test is not required by code--basically, something in the... Read more

Forum topic

Hi there colleagues!

Out of curiosity, do you plan on attending Greenbuild in person in San Diego in September? My staff asked me if we were going and my answer is partially contingent on the extent to which attending would mean getting to see some of our favorite people (read: all of you). Looking forward to taking the temperature of... Read more

Forum topic

Hi all!

I've heard several people talk about developing tools for assessing/codifying a client's values for a project as part of an integrated design process (ie. a set of questions, survey, etc.). Would anyone be willing to share?

(Z, are you listening? I specifically recall you mentioning a tool like this...)

Thanks!... Read more

Product Guide

Caseworks can be made from unsustainable wood and other materials, and with adhesives and finishes that offgas formaldehyde and other hazardous compounds.

BuildingGreen-Approved Casework

Approved caseworks are:

made from FSC-certified wood or rapidly renewable materials verified as low emitting using CDPH Standard Method or a... Read more

Forum topic

Hi, folks! 

I was recently asked if BuildingGreen could connect prospective speakers to an event organizer in Chicago. Beyond the leaders in the BuildingGreen networks relayed, I wanted to share that the exercise led me to the Women and Climate speaker database: https://www.womenandclimate.co/speaker-database 

When filtering by... Read more

Forum topic

Hi All,

Has anyone dug into ASHRAE 2016 as part of the new v4.1 requirements or as codes start to adopt it? I recently presented on this and thought I should check my math to make sure I'm understanding and communicating this correctly.

My understanding is that there is a new reference baseline, that is essentially the ASHRAE 2004... Read more

Forum topic

Following up on one of our conversations on the vision vacuum and sustainability beyond certifications, I would like to help facilitate an offline conversation with anyone working within their firm to use the AIA COTE measures as a guiding framework in their firms/projects. Attached are my slides on my first pass at thinking about this at Page... Read more

Sales page

 

 

Join Brent & Alex to learn what's new and what's been updated in our BuildingGreen Guide to Thermal Insulation, Fourth Edition, including what you should know about:

Performance Health Environmental considerations Building science

So much has changed so quickly!

Our 30-minute roundtable... Read more

Forum topic

Good morning, All,

Just a bit of news this morning.  My family and I are moving back out west!  I am continuing in my current role with EwingCole, but will be doing so from Portland, Oregon.  Although North Carolina has a been a wonderful place for us for the past 13 years, it is time to be close to family in the northwest and southwest... Read more

Quiz

Welcome to the quiz portion of Deep Dive into the Integrative Process with Marcus Sheffer (recorded webinar)

Learning Objectives
Upon completing this course, participants will be able to:


Define “integrative process,” understand its role in LEED BD+C v4 and v4.1, and leverage its power to promote advanced sustainability goals... Read more

Forum topic

Have any of you relied on Green Badger for LEED documentation on projects?

I am familiar with the tool and know Tommy from my time in Atlanta, but have not used it on a construction project.

Have you found value? Thoughts?

Either way, they publish a pretty nifty "LEED v4 Construction Tool Kit" that may be useful for your... Read more

Quiz

Welcome to the quiz portion of The Urgency of Embodied Carbon and What You Can Do About It​​!

Learning Objectives
Upon completing this course, participants will be able to:


Define “embodied carbon” and explain why embodied carbon is a significant source of greenhouse gas emissions, which threaten health and safety... Read more

Forum topic

Greetings to all of the AEC SD Leaders (a.k.a. the Green Gurus)!

Over the last two months, the 32-member Build-Back-Better (BBB) letter working group has developed a robust list of first 100-days, built-environment-focused executive actions for the Biden administration to consider. Kara Kempski, the AIA’s Director of Federal Relations,... Read more

Peer Network Event