BuildingGreen Report

Forum topic

Hello Green Gurus,

Here is the information for January's Peer Networks Webinar, The AEC Industry is in the Driver's Seat: Strategies to reduce waste & carbon emissions. We hope you will join us!

Register HERE

The AEC Industry is in the Driver's Seat: Strategies to reduce waste & carbon emissions
Thursday,... Read more

Forum topic

Hi all-

We are dabbling in developing an official research component of our firm. We have collaborated with a class at a local university and are looking for ways to take our research to a higher level. I'm curious how some of the other firms doing design or building technology research approach the process. For instance, do you have a... Read more

Author

Alena Jumplot

Forum topic

Hi:

I encourage you to review and sign this letter. 

Notes from BDC follow:

Really appreciate the outpouring of support we've received so far on this letter! Various groups let us know that they would like additional time to review, so we've decided to extend the deadline from June 23 to Thursday, July 14 at 2pm.

As... Read more

Forum topic

Hello Green Gurus,

Want to make your virtual meetings wildly effective, connective, and fun? This fall we are delighted to partner with Julie Huffaker from Deeper Funner Change to bring you a series of 5 online workshops that will teach you skills to improve all your virtual meetings.

Julie brings more than 25 years of experience... Read more

Forum topic

Looking for 2-more flushometer style dual-flush flush valves to put in a public project spec alongside sloan uppercut and cannot seem to  find any.  Does anyone have any that they have used?

Thanks in advance!

Team Group

Forum topic

Hey everyone, 

With the coming In-Use Off-Road Diesel-Fueled Fleets Regulation | California Air Resources Board we have been doing some research on availability of R-99 fuel prior to the January 1 start date. One thing we aren't finding in the research is an estimate of cost impacts. Has anyone started rolling out R-99 on their sites yet... Read more

Product Guide

An induction range capable of replacing a standard gas range offers the potential of significantly reducing the energy required for ventilation in a commercial kitchen and improves IAQ at home.

BuildingGreen-Approved Ranges

We look for commercial-scale as well as residential induction cooktops and ranges designed to reduce indoor... Read more

Forum topic

Hi folks,

I'm looking into lower-carbon pipe options for HVAC and plumbing. The MEP 2040 has slides from a Buro Happold study in 2020 showing PEX to be much lower in embodied carbon than copper, which is unsurprising. CPVC is also a lower-carbon option.

But PVC has its issues and neither PVC nor PEX are recyclable (especially if... Read more

Forum topic

Hi Advising Leaders!

Lets get this forum going by introducing ourselves (yes, I know we mostly know each other, but just to be sure). And sharing what's most exciting and/or bugging us these days. Oh, and if you haven't already, please fill out your BG.com profile with a picture and bio. 

I'll start. I'm Nadav, president at... Read more

Author

Forum topic

This is deep nerdy stuff, so don't say you haven't been warned.  ASHRAE has opened the first public review to its net zero standard (228).  Here's the blurb:

Standard Method for Evaluating Zero Net Energy and Zero Net Carbon Building Performance ASHRAE Standard 228-202x sets requirements for evaluating whether a building or group of... Read more

Forum topic

We are having trouble sourcing a LEED compliant wallcovering adhesive. We specified Roman Pro-880 which is low VOC but doesn't have sufficient back up for TVOCs. Have you had success with other products?

Forum topic

"The man with one watch knows what time it is; the man with two is never sure."   --Segal's Law

We recently purchased two indoor air quality meters in the $200-$300 range and find that they never agree, not even close. I would like to find out what other people's experiences have been, and if they have tested affordable models that... Read more

Quiz

Welcome to the quiz portion of Building as an Organism: Understanding the Integrative Process Credit in LEED v4 Projects (recorded webcast)

Learning Objectives
Upon completing this course, participants will be able to:


1. Explain why integrative design is the key to cost-effective, high performance green buildings and LEED... Read more

Forum topic

Hey SDL,

I'm curious if anybody out there has developed specification language requiring a certain level of airtightness (as assessed via one or a series of blower door tests) for a commercial project when it is not going for a Passive House certification and a blower door test is not required by code--basically, something in the... Read more

Forum topic

Hi all,

We have a newly constructed, core/shell project having some hot water issues in the core restrooms.

There is a 0.35 Toto lav installed throughout. The hot water heaters are adjacent on each floor, located in the janitor closets. We did the math, and there could be a gallon of water standing and cooling in the pipe between... Read more

Forum topic

I am very interested to understand the deployment of LED temp jobsite lighting on a national level.  I think this all goes back to the low emitting jobsite.

1. Does your firm utilize temp jobsite lighting on your projects?  

2. Is this every project or a percentage of projects?

3. In your state or area is it prevalent, one... Read more