Forum topic
We have an MEP engineer that is calculating peak loads at about 6 times passive house levels on a large commercial building that is at or near passive house levels of insulation and air infiltration. We suspect one reason is that he is figuring a 50% efficiency level for the ERV. We are showing him ERV systems with 80-90% efficiency, but they... Read more
Forum topic
Hi, folks!
I was recently asked if BuildingGreen could connect prospective speakers to an event organizer in Chicago. Beyond the leaders in the BuildingGreen networks relayed, I wanted to share that the exercise led me to the Women and Climate speaker database: https://www.womenandclimate.co/speaker-database
When filtering by... Read more
Quiz
Welcome to the quiz portion of Green Design: What's Love Got to Do with It?
Learning Objectives
Upon completing this course, participants will be able to:
1. Summarize how designers are better able to fulfill the full promise of sustainability by embracing sensory experience.
2. Broaden the sustainable design... Read more
Forum topic
Happy Thursday, all!
I will be presenting with my colleague, Emily Hoffman, and our counterpart from Seattle, Duane Jonlin, on how firms can contribute more to aggressive energy and carbon targets, from the perspective of three people that see thousands of projects each year. We see the best and the worst, and we're convinced that our... Read more
Product Guide
Caseworks can be made from unsustainable wood and other materials, and with adhesives and finishes that offgas formaldehyde and other hazardous compounds.
BuildingGreen-Approved Casework
Approved caseworks are:
made from FSC-certified wood or rapidly renewable materials verified as low emitting using CDPH Standard Method or a... Read moreForum topic
Hi all,
We have a newly constructed, core/shell project having some hot water issues in the core restrooms.
There is a 0.35 Toto lav installed throughout. The hot water heaters are adjacent on each floor, located in the janitor closets. We did the math, and there could be a gallon of water standing and cooling in the pipe between... Read more
Forum topic
If anyone else has gotten confused going between parts-per-million and percentages (parts per hundred!) for material reporting here's a little infographic that might help. Feel free to use or improve!
Reports, Courses, Study Guides, Live Webinars
Currently not for sale, being updated and re-released in November 2021.
New Guide to Thermal Insulation Report
The BuildingGreen Guide to Insulation provides detailed guidance on insulation products and practices, including cost comparisons and detailed recommendations on what insulation to use, and what to avoid. It's a treasure... Read more
Forum topic
Hi folks,
AIA COTE National is looking for Techincal Reviewers for the 2025 awards. Interested, or know someone who might be? Sign up here: https://form.jotform.com/231175886103153
Thanks!
Sales page
Are you a design or building professional who wants to learn more about sustainability—such as how to do energy modeling, improve the building envelope, or use renewables on a project? Now more than ever, it's time to join the sustainable... Read more
Product Guide
Pipe that delivers domestic water in North America is typically made from copper, chlorinated polyvinyl chloride (CPVC), cross-linked polyethylene (PEX), all of which present environmental challenges. Bimodal polyethylene (PE-RT) and polypropylene (PP) are potential alternatives with lower climate and health impacts.
... Read more
Forum topic
All,
I've probably spoken to a few of you over the phone, but I wanted to make sure all of you know that we are hosting a 4 part webinar series on our Tally LCA software, kicking off tomorrow 10/10. We just released the new of Tally version and ended up doing far more development work than initially anticipated, in no small part due to... Read more
Forum topic
Has anyone completed an LCA for an engineering structures lab, particularly one that has a strong wall and strong floor?
Forum topic
Hi Everyone - I hope this isn't a repeat topic. We are starting to get familiar with TallyCAT at SAR+ and have a few people testing our projects in it. Is anyone willing to help us troubleshoot or share lessons learned? We're running into a few errors and wonder if our Revit models and workflow are the issue, or if we need to be doing something... Read more
Author
RoseAnn’s role at BuildingGreen as Peer Networks Manager focuses on Peer Networks projects and planning events, including annual Peer Network Summits.
Prior to BuildingGreen, RoseAnn worked in the nonprofit sector in customer-service based roles which allowed her to reconnect with her local community soon after earning her... Read more
Forum topic
Hi Carbon Working Group,
It’s been a while since our last online meeting on 3/31 –- admittedly, a bit too long -- so I wanted to share some updates. You might have seen Candice Pearson’s 5/13 post about the structure of the Contractor’s Commitment and how it’s evolving into a set of guidelines available not only to our SCL Group but to... Read more
Forum topic
What thoughts do you have? What have others said that you feel we want to capture?
The Vision Vacuum: What’s driving environmental and social progress in architecture today? What should be driving it, and where should we be going?