Forum topic
***Cross-posting this from SCL Group***
Last year I was approached by Green Advantage, remember them from like 2005? There has been a LEED innovation credit for as long as I can remember.
Has anyone seen employed Green Advantage recently? Is anyone asking for it?
Do you see value in GCs/CMs/trades having this training... Read more
Forum topic
Hi All,
Has anyone dug into ASHRAE 2016 as part of the new v4.1 requirements or as codes start to adopt it? I recently presented on this and thought I should check my math to make sure I'm understanding and communicating this correctly.
My understanding is that there is a new reference baseline, that is essentially the ASHRAE 2004... Read more
Forum topic
Hi folks,
I'm looking into lower-carbon pipe options for HVAC and plumbing. The MEP 2040 has slides from a Buro Happold study in 2020 showing PEX to be much lower in embodied carbon than copper, which is unsurprising. CPVC is also a lower-carbon option.
But PVC has its issues and neither PVC nor PEX are recyclable (especially if... Read more
Forum topic
Tomorrow is my last day at FXCollaborative before I head back to school. It has been such a gift to engage with you all over the past 10 years. Please stay in touch - my contact information is ilanajudah@gmail.com. I am headed out to UBC next week to do a deep dive into resilience and adaptation in urban environments.
FXCollaborative... Read more
Quiz
Welcome to the quiz portion of Essential Playbook to Managing LEED Construction.
Learning Objectives
Upon completing this course, participants will be able to:
1. Understand the transition from LEED BD+C or ID+C v4 to LEED v4.1, especially in regard to material-related credits.
2. Discern how to properly... Read more
Forum topic
Dear Green Gurus: I'm so sorry to have missed seeing many of you at AIA last week. I heard the BG and COTE events were the highlights of the week! Congrats.
I'm sure by now you've heard of the dreadful Supreme Court decision about the EPA. I thought I'd share a helpful, if not sobering, perspective in an Op-Ed today in the Washington... Read more
Reports, Courses, Study Guides, Live Webinars
This webinar occurred Thursday, December 15.
Attendance confirmation closed Friday, December 30.
Whether it’s the flooding in Pakistan, the devastation caused by Hurricane Ian in Florida, or the record-breaking wildfire season in Europe, climate change is in the news daily. Just as there’s an urgent need to reduce... Read more
Forum topic
I was recently tasked by my CEO to uncover some qualitative (interviews) and quantitative (surveys) data within our organization related to the value remote working has had on our organization. He's specifically interested in questions such as how this experience has enhanced our value as teams, unity or disunity as a firm? Where has it ... Read more
Forum topic
Hey SDL,
I'm curious if anybody out there has developed specification language requiring a certain level of airtightness (as assessed via one or a series of blower door tests) for a commercial project when it is not going for a Passive House certification and a blower door test is not required by code--basically, something in the... Read more
Product Guide
Gypsum is calcium sulfate dehydrate, which is mined or produced as a byproduct of flue gas desulphurization (FGD) from coal-fired power plants. FGD gypsum may contain trace contaminants from coal processing, but not enough to represent a hazard to users. Years ago, some imported products created indoor air quality problems that required... Read more
Forum topic
Hi Everyone. Hope you and your families are all healthy and safe.
We are starting to figure out how we are going to implement the Contractors Commitment at my company, and we're using the opportunity to simultaneously set corporate wide and jobsite metrics and goals for sustainability tracking.
Each year we issue a sustainability... Read more
Forum topic
Thanks to SERA especially David, Kira and Clark for an inspirational conversation with Paul Hawken about his latest book. I know I needed a positive perspective! Then I found this great "Regeneration Anthem" song and had to share.
https://regeneration.org/news/210915-we-can-change-world-regeneration-an...
Happy Fall to all.
... Read moreForum topic
Hi, folks!
I was recently asked if BuildingGreen could connect prospective speakers to an event organizer in Chicago. Beyond the leaders in the BuildingGreen networks relayed, I wanted to share that the exercise led me to the Women and Climate speaker database: https://www.womenandclimate.co/speaker-database
When filtering by... Read more
Forum topic
Hi all,
We have a newly constructed, core/shell project having some hot water issues in the core restrooms.
There is a 0.35 Toto lav installed throughout. The hot water heaters are adjacent on each floor, located in the janitor closets. We did the math, and there could be a gallon of water standing and cooling in the pipe between... Read more