BuildingGreen Report

Forum topic

Hello fellow sustainable design leaders! I am about to kick off an intensive effort here at EHDD to refine our internal standards for materials. We will be considering both GWP as well as the health of materials (avoiding harmful chemicals). In addition to setting the standards, I will be working to develop a process to vet materials before... Read more

Forum topic

Hello everyone - 

I'm writing today to let you all know that as of this month, I am retiring from SERA, and that I'm going to be beginning a new journey as a consultant/volunteer!

I'm going to continue dedicating my time to policy and advocacy work (focused on decarbonizing the built environment) but now I'll be doing it as a free... Read more

Forum topic

A couple Minnesota cities are considering adding electrification to their sustainable building policy (required for new construction receiving City financial assistance). Concerned that the market isn't ready for a full-on mandate, they are considering a more moderate approach of requiring developers/design teams to conduct an electrification... Read more

Forum topic

Hello all,

I need future weather files for a project. We are looking at three years, 2050, 2075, and 2095 using two climate change scenarios, low emissions, and high emissions. I have seen ARUP's Weathershift site that uses RCP 8.5 and RCP 4.5. Are we assuming that 2.6 is not achievable? I would have used this as a low emissions scenario... Read more

Forum topic

Hi All, I was initially reluctant to share this, but I've seen similar posts and I think it's in line with our mission and interests so I'll go ahead with it.

Tomorrow 12/9 at 1 PM EST I'm moderating a panel of industry leaders in public health (as it pertains to buildings), construction finance, and project development to review the... Read more

Forum topic

Looking for an example or case study for a building utilizing a radiant heating/cooling in climate zone 4a. General use type is office with some public assembly spaces, total of 85,000 sf.

As usual, everyone, especially mechanical engineer, is terrified by the thought of "condensation." So far, I read a DGWW case study, "Energy... Read more

Forum topic

Hello lovely Green Gurus. Hope you all are well. I am wondering if anyone has installed an indoor sports floor that performed well and is low-emitting. This is for a multi-purpose gymnasium at a community center. Any chance?  Thanks All!

Quiz

Welcome to the quiz portion of Choosing Insulation: Health and Environmental Considerations – Unit 1.

Learning Objectives
Upon completing this course, participants will be able to:


 

1. Discuss how insulation works.
2. Summarize how insulation performance is measured and reported.
3. Recount the wide... Read more

Forum topic

Hi all,

I've been working on a LEED project in California for months and our energy modeler wants to use the LI 10480 Title 24 2019 pipeline to demonstrate compliance under LEEDv4. Only problem is, I've never done it that way before, and our modeler and I are consistently speaking in different languages. Anyone done a project under this... Read more

Forum topic

Hi friends,

We recently tracked our water consumption on site during the structural demolition of some existing reinforced concrete buildings.  The new OSHA silica regulations required us to keep dust to virtually zero, so we had a bunch of mist cannons and water hoses pumping water around the clock.  We consumed ~855,000 gallons in a... Read more

Forum topic

Hello Sustainable Construction Leaders,

It's come to our attention that although we shared the slides from last fall's all-network Show & Tell in Atlanta, we neglected to include the presentations from the SCL Summit itself. Since we believe in "better late than never," here they are!

As a reminder: we have permission from... Read more

Product Guide

Indoor pollutants can cause health problems and disrupt HVAC system functioning.

BuildingGreen-Approved Filtration

BuildingGreen approves a variety of equipment, filters, and pre-filters that remove particulates and contaminants, minimize pressure drop, or reduce pollution from operations. Products include:

MERV 13 or higher... Read more

Campus-wide Group

Quiz

Welcome to the quiz portion of An Advocate’s Guide to Resilience Regulations!

Learning Objectives
Upon completing this course, participants will be able to:


1. Explain how U.S. municipalities are using codes to improve the resilience of the built environment in the face of worsening climate change.

2. Delineate five... Read more

Forum topic

I'm working with a project team that is looking into bird control options to prevent nesting/roosting/pooping on the scrim that is designed to scrim their building's facade.  They are looking at electrified tape, repellents, laser systems, etc -- Options that don't dramatically impact the building design.  The products they're looking at claim... Read more

Forum topic

We have a client who is asking us to design a roughly 10 ksf Wellness Center for PHIUS 2021 certification.  The program includes several high density assembly type spaces - roughly 300 person peak occupant load for the building.  The Criteria Calculator that the architect showed us puts the building peak cooling load at 4 BTUH/sf (3000 sf/ton... Read more

Reports, Courses, Study Guides, Live Webinars

Tuesday, June 20th 2:00pm Eastern (11am Pacific)

Practitioners interested in reducing the embodied carbon of buildings are likely now used to considering the impact of different materials, like mass timber or low-carbon concrete. Low-carbon construction, however, may be less familiar. 

Contractors are just... Read more

Forum topic

Hi MEP Leaders,

Just a reminder that our monthly call is next Tuesday, July 11, at 2pm ET. Chris Colasanti will be presenting on impacts of different facade characteristics on overall energy performance! 

All Network members are welcome to join. Here is the agenda, and below is the Zoom info:

Join Zoom Meeting
https... Read more