BuildingGreen Report

Forum topic

The results from the "CogFx" study are compelling, showing that people in environments with low VOCs and low ambient CO2 levels score higher on tests of cognitive function.  Specifically, they show that providing 40cfm of outdoor air per (actual live) occupant results in significantly higher scores than even the "Enhanced Ventilation" scheme... Read more

Campus-wide Group

Forum topic

Hi everyone - in doing a carbon footprint for our firm, does anyone know if buildings that we design as Architects considered scope 3 emissions, or are they beyond the boundary of emissions? LMN's buildings, despite best efforts, are cumulatively multiple orders of magnitude above our scope 1 and 2 emissions. We have never included these... Read more

Forum topic

Has anyone documented the Food Alternatives credit as part of WELL or as an innovation credit in LEED?

Forum topic

Hello! 

We have several projects that are either pending ILFI Zero Carbon certification or the owner is planning to purchase offsets to cover construction emissions. Thus far, I have not considered this in our corporate footprint reporting. However, we are including A5 emissions whenever feasible and multiplying that performance over the... Read more

Quiz

Welcome to the quiz portion of Choosing Insulation: Health and Environmental Considerations – Unit 1.

Learning Objectives
Upon completing this course, participants will be able to:


 

1. Discuss how insulation works.
2. Summarize how insulation performance is measured and reported.
3. Recount the wide... Read more

Forum topic

Hi all,

I'm curious if anyone has insight as to the "New Federal Building Performance Standards" that were announced in May of 2021 and then referenced again when E.O. 14057 came out. The memorandum for heads of agencies that was sent out with E.O. 14057 said that the CEQ would issue these standards, but I can't find a commitment to when... Read more

Forum topic

A couple Minnesota cities are considering adding electrification to their sustainable building policy (required for new construction receiving City financial assistance). Concerned that the market isn't ready for a full-on mandate, they are considering a more moderate approach of requiring developers/design teams to conduct an electrification... Read more

Forum topic

Looking for an example or case study for a building utilizing a radiant heating/cooling in climate zone 4a. General use type is office with some public assembly spaces, total of 85,000 sf.

As usual, everyone, especially mechanical engineer, is terrified by the thought of "condensation." So far, I read a DGWW case study, "Energy... Read more

Forum topic

I'm looking to compile an outdoor weather station for a local project, and we'd like to add local outdoor CO2 information to our data. I usually work with Onset HOBO products, but they don't offer an outdoor CO2 sensor. Their weather stations can take data from any CO2 sensor with an analog output - does anyone have any suggestions?

Forum topic

Hello all, 

Wondering if anyone has experience with lead limits in electrical cable and wiring? 

LEED for Healthcare allows a limit of 300 ppm of lead in electrical wire and cabling - my search for compliant products has been all dead ends. (MRc PBT Source Reduction - lead, cadmium, and copper)

Acceptable regulations for... Read more

Forum topic

I'm working with a project team that is looking into bird control options to prevent nesting/roosting/pooping on the scrim that is designed to scrim their building's facade.  They are looking at electrified tape, repellents, laser systems, etc -- Options that don't dramatically impact the building design.  The products they're looking at claim... Read more

Team Group

Forum topic

Resilience Resource Database

The Defining and Measuring Resilient Outcomes Working Group has been developing a Resilience Resource Database as a repository for resources related to the topic of resilience in our built environment. 

This database and map are endeavoring to show resources for resilient design across the country to... Read more

Basic page

Peer Networks SDL Green Gurus Member List Webinars Calendar Resources Help Forum Shared files About

Forum topic

We have a client who is asking us to design a roughly 10 ksf Wellness Center for PHIUS 2021 certification.  The program includes several high density assembly type spaces - roughly 300 person peak occupant load for the building.  The Criteria Calculator that the architect showed us puts the building peak cooling load at 4 BTUH/sf (3000 sf/ton... Read more