Championing the
Changemakers
BuildingGreen champions the changemakers in sustainable design and building, with trusted insight, unparalleled education, and communities that are transforming the industry.
Log in to your profile
Image: Piranka
Forum topic
I'm hoping someone knows the anser to this question. For the LEED ND certification the minimum requirement is "The LEED project should contain at least two habitable buildings and be no larger than 1500 acres." Does habitable mean buildings with dwelling units?
Quiz
Welcome to the quiz portion of Existing Buildings Are Architecture’s Future!
Learning Objectives
Upon completing this course, participants will be able to:
Forum topic
Apologize in advance if this has been posted before but we are trying to get manufacturers of stage curtains to give documentation that proves that the product does not have halogenated fire retardants. Manufacturers say they don't have them or concentrations are limited to 100ppm but they don't seem to have documentation to provide for it.... Read more
Forum topic
Greetings Gurus, following the AIA COTE Design for Economy concept, does anyone have a resource for a list of building efficiency ratio "targets" by space type? I've always struggled with this initiative.
Forum topic
I know there are a few of us WELL Performamce Testing Agents / Organizations represented in this group. In the wake of technology talks on this weeks update calls from IWBI, I'm wondering if anyone would be interested in a best practices and equipment small group discussion within the safe space of Green Gurus? Let me know!
Forum topic
Does anyone have an experience on recycling/reusing architectural glazing? We have a sizable glazing replacement project, and I am realizing how difficult it is to find a way to prevent the glazing from going into the landfill. So far, I have reached out to Terrazzo (aggregate) manufacturers, Glass Recycling Coalition, Architectural Glass... Read more
Forum topic
Hello, what acceptable levels of air quality are you using to evaluate natural ventilation strategies for your projects? In our Living Building we only open windows when PM10, PM2.5, etc. are within LBC and WELL limits. In a seasonally smoggy urban environment, this limits how often we can utilize natural ventilation even if the outside... Read more
Product Guide
Ventilation fans, kitchen range hoods, and laboratory fume hoods can use significant amounts of energy from both the fan motor and from venting heated/cooled air out of the building—air that then has to be replaced and conditioned by energy-intensive HVAC systems.
BuildingGreen-Approved Ventilation Fans
BuildingGreen ventilation... Read more
Forum topic
Does anyone here have a draft spec for low embodied carbon concrete they could share? I see the GSA has a standards sheet with MGWP limits, but we are hoping to actually specify the mix for upcoming projects.
Quiz
Welcome to the quiz portion of VOCs: Still Here, Still Making Us Sick!
Important: This quiz covers all related articles within this topic. Scroll to the bottom of the article page to find links to all the articles covered by this quiz.
Learning Objectives
Upon completing this course, participants will be able to:
1.... Read more
Forum topic
I opened IE11 (Internet Explorer 11) today, and saw a message indicating IE11 will be retired June 15th, 2022. While I have no personal attachment to IE11, it was the only internet browser I could consistantly get to open LEED Online credit templates on the actual website.
Has anyone found another way to be able to fill out LEED credit... Read more
Reports, Courses, Study Guides, Live Webinars
ON SALE NOW - for a limited time, get the Guide for $69.00
If you are interested in sharing this guide within your organization and adding a copy to your library, please purchase the guide's site license. The site license permits the purchaser to share the PDF Guide file within their company/organization and post it on their... Read more
Forum topic
This might be going down a rabbit hole, but in moving to California this year I noticed that "zero net energy" (ZNE) is the standard term, whereas "net zero energy" (NZE) was more common back east. The DOE's 2015 definition (below) uses "zero energy building" (ZEB), which to me implies a building uses no energy at all.
Regional... Read more
Forum topic
It’s here! By popular demand we’re re-running the SDL Salary Survey that we last ran in 2015.
This is for people who are currently in an SD Leader role at a firm. We’re sending this invitation out on both the Green Gurus and the SD Leaders forums, because some of you are still in transition and haven’t moved into the SD Leader forum yet... Read more
Forum topic
see IFTF- A New Story to Spark the Future of Climate Action
and chek out their Climate Action Map download
Author
Charlotte has been the lead customer service representative at BuildingGreen for 25 years.
Having been involved in the nuts and bolts of customer service and accounting throughout various phases of the company’s development, Charlotte’s historical knowledge is immensely helpful to BuildingGreen’s staff and customers. Customers know her... Read more