BuildingGreen Report

Forum topic

Who else is playing in this year’s #SustainabilityScavengerHunt by BE+!?

Meredith Elbaum and team at Built Environment Plus are launching the second annual hunt this Friday. Teams of up to four people compete over a couple of weeks to complete missions and bring awareness to environmental topics.

It was a lot of fun last year - we... Read more

Basic page

Peer Networks Application for Peer Network Membership Sustainable Community Design Leaders

The Sustainable Community Design Leaders Peer Network brings together planners, architects, landscape architects, and allied leaders who are committed to leveraging the... Read more

Forum topic

Hi all, we are embarking on an effort to standardize our LCA process in order to maintain a firmwide database of embodied carbon intensity from which we can create internal baselines and targets. I was wondering how other offices are setting boundaries for their LCA efforts. Below is our starting point. Most LCA will be conducted using Tally.... Read more

Quiz

Welcome to the quiz portion of When Passive House Goes Big!

Learning Objectives
Upon completing this course, participants will be able to:


Evaluate the main barriers to achieving the Passive House Standard on a large, urban project.

Identify design strategies for successfully and cost-effectively achieving the... Read more

Forum topic

I have been watching LEED Zero for a while, and have appreciated certain things, but one thing I think is an absolute disaster is their allowance of mainline RECs for claiming Zero Energy and Zero Carbon performance.  I just asked this question on the LEED Zero webinar, and the panelist basically said, "it's part of LEED Zero, therefore it is... Read more

Forum topic

Hi all!

I'm working on my first energy positive / passive house multifamily building and trying to figure out the trash/recycling chute. I am curious what solutions you have employed to make the trash chute air tight? We have excluded the whole chute from the envelope. Do you use airtight doors (and which ones?) at each floor trash/... Read more

Forum topic

Can you comment on successful ways you have used eQUEST and pitfalls you have seen? We are considering training our architects to use it for early building analysis on all projects. 

Forum topic

Does adding solar panels reduce a building's EUI?

Existing operational use of a building is 80 kBtu/sf/year. When we add solar, it will change the source of energy but does not change the usage.

My understanding is that the EUI does not change, but it would be good to hear from others.

It's energy consumption at the point... Read more

Team Group

Author

Pat U. Mellona

Forum topic

My firm is mobilizing for a year of carbon awareness and reduction that goes beyond the energy consumption of our designs. We are looking to hire a full time person to take on LCA tracking for our current projects. Ideally it is a climate crisis super-hero of sorts who could also look at our design process and help develop multi-faceted... Read more

Forum topic

Has anyone had a Contractor track GHG emissions during construction? If so, any advice on how to include that in the project specifications?

Thanks!

Yarden

Forum topic

If you haven't seen it yet, today's U.N. report "Making Peace With Nature" tackles climate change, biodiversity loss, and pollution jointly within the framework of the Sustainable Development Goals. 

The analysis is anchored in current economic, social and ecological reality and framed by economics and the 2030 Agenda for Sustainable... Read more

Forum topic

Seeing Jen's post prompted me to write in support of the Madison Park Technical Vocational High School program (Greenbuild Legacy Project). I spoke to the students earlier in the year and it is a great program. I'll reach out to our HR about interns.

I am the Director of Facilities Management Integration and Sustainability for Shawmut... Read more

Forum topic

Happy Friday, SDL!

We're running a Tally WBLCA for an environmental education center, which has a very small floor area but a fairly robust concrete/steel structure. Still, I was surprised to find an intensity of over 1,000 kgCO2/m2 for the building.

This is way higher than the general benchmarks I've found in the CLF's database,... Read more

Forum topic

I am looking for case studies/trying to identify buildings using concrete mixes with upwards of 30% replacement of cement by SCMs.  I've been in conversations with some structural engineers who are interested in lowering embodied carbon in upcoming projects, but would like to see examples of where this level of replacement has been successfully... Read more

Quiz

Welcome to the quiz portion of Can Concrete Save Us? Locking Up Carbon in Building Materials

Learning Objectives
Upon completing this course, participants will be able to:


 

1. Explain current strategies of carbon capture and sequestration (CCS).
2. Detail how concrete offers another possible pathway to... Read more