Forum topic
Has anyone documented the Food Alternatives credit as part of WELL or as an innovation credit in LEED?
Forum topic
Hello all,
I need future weather files for a project. We are looking at three years, 2050, 2075, and 2095 using two climate change scenarios, low emissions, and high emissions. I have seen ARUP's Weathershift site that uses RCP 8.5 and RCP 4.5. Are we assuming that 2.6 is not achievable? I would have used this as a low emissions scenario... Read more
Forum topic
First, there was Energy Use reductions
Then there was embodied carbon
Soon it will be refrigerant use/leakage calculations
…and much more
As coordinators and leaders of project teams, what does this look like for the practicing architect and our collaborators?
I have no idea. BUT I’m guessing someone is... Read more
Forum topic
Hi all,
Thanks again to those who presented at the AIA Show & Tell! Here are the slides for some of the fascinating presentations we saw. Please do not share the slides outside of the networks unless they are marked “PUBLIC.”
There may be more to come; if you presented but did not yet provide permission for your slides to be... Read more
Forum topic
Hello all,
Wondering if anyone has experience with lead limits in electrical cable and wiring?
LEED for Healthcare allows a limit of 300 ppm of lead in electrical wire and cabling - my search for compliant products has been all dead ends. (MRc PBT Source Reduction - lead, cadmium, and copper)
Acceptable regulations for... Read more
Forum topic
Hi everyone,
We're pitching a green wall to a client for a project in NYC and are looking for recommendations on systems/companies. We've done them locally, but the company we've worked with only services the Boston area. There are so many companies out there now that we'd rather go with one that's recommended. Thanks in advance for... Read more
Forum topic
Hi All, I was initially reluctant to share this, but I've seen similar posts and I think it's in line with our mission and interests so I'll go ahead with it.
Tomorrow 12/9 at 1 PM EST I'm moderating a panel of industry leaders in public health (as it pertains to buildings), construction finance, and project development to review the... Read more
Forum topic
Here is a fundamental question regarding measuring operational carbon emissions that I'm sure many of you can clarify for me: Let's say you are considering design options and you want to know the relative contribution of GWP of adding an additional inch of continuous insulation to the building envelope. The GWP from embodied carbon will... Read more
Forum topic
We have a client who is asking us to design a roughly 10 ksf Wellness Center for PHIUS 2021 certification. The program includes several high density assembly type spaces - roughly 300 person peak occupant load for the building. The Criteria Calculator that the architect showed us puts the building peak cooling load at 4 BTUH/sf (3000 sf/ton... Read more
Forum topic
On LEEDuser we divide checklists into multiple project phases. Specifically:
Before the performance period Construction Construction documents Design development During the performance period Operations & maintenance Pre-design Schematic designHow many of these phases are relevant for BIT best practices?
Note that we also... Read more
Forum topic
Hello everyone -
I'm writing today to let you all know that as of this month, I am retiring from SERA, and that I'm going to be beginning a new journey as a consultant/volunteer!
I'm going to continue dedicating my time to policy and advocacy work (focused on decarbonizing the built environment) but now I'll be doing it as a free... Read more
Forum topic
Friends,
Through AIA work I have been working with Kim Shinn from TLC Engineering. Kim is involved on the ASHRAE 209 development and has been advocating that the AIA, ASHRAE and USGBC align around this standard. Personally I think this is a good idea as I expect that this standard could easily make it's way into regulations and contracts... Read more
Author
Anne Hicks Harney, FAIA, has more than 30 years of experience, focusing on high-quality design imbued with a solid technical and sustainable foundation. At Long Green Specs, she provides sustainability-focused construction specifications and building material expertise to architectural firms across the country. She was chair of the AIA... Read more
Product Guide
Board insulation has good thermal performance ranging from about R-4 to R-8 and is used as an integral part of a building envelope’s continuous insulation system.
Because board insulation is used on the building exterior, it is not always subject to the same material health and emissions requirements as batt insulation used inside the... Read more
Forum topic
The Water Sub-Group met today. This group is working on three items:
1. Project Water Plan Template
2. Project Water Tracking Form Template
3. Research and Resources Document
The Meeting minutes are attached. The next meeting is 5/19/20 @ 2:30 PM CST, via webex and teleconference. Please contact me if you would... Read more