Hi all,

I'm curious how various firms are approaching their own office projects, re green building certifications. I'm especially interested in medium-large firms that have multiple offices, but policies and processes from small firms may still be instructive.

Do you have a firm-wide policy or is it a case-by-case thing? Has... Read more

Forum topic

Hello Sustainable Construction Leaders,

It's come to our attention that although we shared the slides from last fall's all-network Show & Tell in Atlanta, we neglected to include the presentations from the SCL Summit itself. Since we believe in "better late than never," here they are!

As a reminder: we have permission from... Read more

Product Guide

As with most office furniture, systems furniture can be made from unsustainable materials and use adhesives and finishes that emit formaldehyde or other hazardous compounds.

BuildingGreen-Approved Furniture

BuildingGreen approves furnishings that:

are certified to BIFMA’s multi-attribute level 3 standard, which requires low... Read more

Forum topic

Hello! 

We have several projects that are either pending ILFI Zero Carbon certification or the owner is planning to purchase offsets to cover construction emissions. Thus far, I have not considered this in our corporate footprint reporting. However, we are including A5 emissions whenever feasible and multiplying that performance over the... Read more

Forum topic

I'm looking to compile an outdoor weather station for a local project, and we'd like to add local outdoor CO2 information to our data. I usually work with Onset HOBO products, but they don't offer an outdoor CO2 sensor. Their weather stations can take data from any CO2 sensor with an analog output - does anyone have any suggestions?

Forum topic

The results from the "CogFx" study are compelling, showing that people in environments with low VOCs and low ambient CO2 levels score higher on tests of cognitive function.  Specifically, they show that providing 40cfm of outdoor air per (actual live) occupant results in significantly higher scores than even the "Enhanced Ventilation" scheme... Read more

Forum topic

Hello all,

I need future weather files for a project. We are looking at three years, 2050, 2075, and 2095 using two climate change scenarios, low emissions, and high emissions. I have seen ARUP's Weathershift site that uses RCP 8.5 and RCP 4.5. Are we assuming that 2.6 is not achievable? I would have used this as a low emissions scenario... Read more

Forum topic

Looking for an example or case study for a building utilizing a radiant heating/cooling in climate zone 4a. General use type is office with some public assembly spaces, total of 85,000 sf.

As usual, everyone, especially mechanical engineer, is terrified by the thought of "condensation." So far, I read a DGWW case study, "Energy... Read more

Forum topic

Folks, it is with a heavy heart that I write this: Lance Hosey passed away unexpectedly on Friday. 

Many of you know him from the early days of the SDL group, or as an outsized presence at any of the many conferences where we overlap. He's been a list-maker, poll-taker and all around troublemaker in my life for over 20 years; I know I am... Read more

Reports, Courses, Study Guides, Live Webinars

This webinar occurred Thursday, December 15.

Attendance confirmation closed Friday, December 30.

 

Whether it’s the flooding in Pakistan, the devastation caused by Hurricane Ian in Florida, or the record-breaking wildfire season in Europe, climate change is in the news daily. Just as there’s an urgent need to reduce... Read more

Forum topic

We have a client who is asking us to design a roughly 10 ksf Wellness Center for PHIUS 2021 certification.  The program includes several high density assembly type spaces - roughly 300 person peak occupant load for the building.  The Criteria Calculator that the architect showed us puts the building peak cooling load at 4 BTUH/sf (3000 sf/ton... Read more

Forum topic

My dear collegues,

As I'm sure is true for many of us, the events of the past weeks (months/years/decades...) have emphatically reinforced to me the need for a radical shift in how we meaningfully address JEDI in what we do. One (admittedly small) step I've been thinking about are the statements of reconciliation that have become more... Read more

Quiz

Welcome to the quiz portion of Getting Flame Retardants Out of Foam Insulation.

Learning Objectives
Upon completing this course, participants will be able to:


 

1. Summarize why and how flame retardants are used in foam insulation.
2. Elucidate the case for taking the chemicals out of foam insulation.
3.... Read more

Forum topic

Resilience Resource Database

The Defining and Measuring Resilient Outcomes Working Group has been developing a Resilience Resource Database as a repository for resources related to the topic of resilience in our built environment. 

This database and map are endeavoring to show resources for resilient design across the country to... Read more

Author

Author

Forum topic

https://www.bostonglobe.com/metro/2018/06/04/new-china-policies-spark-di...

New China policies spark disarray in region’s recycling industry
Buried in the mountains of refuse at Casella’s recycling plant in Charlestown are tons of material that should have gone straight to the landfill — from tires and pots to lobster buoys and... Read more